teChniCal data

Kempoweld
Connection voltage
Connection capacity 230 V / 400 V
Main cable / fuses
Connection to wire feeder unit
- Fuse delayed
Loading capacity (nominal values)
Control range 40 steps
Open circuit voltage 40 steps
EN
Open circuit power
Efficiency
Power factor
Temperature class
Operation temperature range
Storage temperature range
Degree of protection
EMC class
Minimun short circuit power Ssc of
supply network *
Cooling unit power
- Fuse delayed
External dimensions
Weight
* See paragraph 2.2
16
3200
3 ~ 400 V 380 V -10 % ... 415 V +6 %
3 ~ 230 V 220 V -10 % ... 240 V +6 %
40 % ED 13,6 kVA
60 % ED 10,0 kVA
100 % ED 6,6 kVA
220 - 240 V 4 x 2,5 mm² / 20 A delayed
380 - 415 V 4 x 2,5 mm² / 16 A delayed
30 V / 250 VA
8 A
40 % ED 320 A / 32 V
60 % ED 265 A / 27 V
100 % ED 205 A / 24 V
40 – 320 A / 15 – 32 V
15 – 40 V
< 50 W
320 A / 32 V 75 %
320 A / 32 V 0,95
H (180 °C)
-20 ... +60 °C
-40 ... +60 °C
IP23S
A
0.9 MVA
- - -
- - -
lenght 990 mm
width 530 mm
height 880 mm
106 kg
3200W
380 V -10 % ... 415 V +6 %
220 V -10 % ... 240 V +6 %
13,6 kVA
10,0 kVA
6,6 kVA
4 x 2,5 mm² / 20 A delayed
4 x 2,5 mm² / 16 A delayed
30 V / 250 VA
8 A
320 A / 32 V
265 A / 27 V
205 A / 24 V
40 – 320 A / 15 – 32 V
15 – 40 V
< 50 W
75 %
0,95
H (180 °C)
-20 ... +60 °C
-40 ... +60 °C
IP23S
A
0.9 MVA
230 V / 250 VA
2 A
990 mm
530 mm
1090 mm
118 kg