3
Connecting System Components
Select the Use the following IP address option.
4.
Set a static IP and Subnet mask address for the port. Select values that do not conflict with
5.
any other machine on your network. Consider using the following values:
IP address: 192.168.125.10
Subnet mask: 255.255.255.0
W
:
ARNING
lustre.config file.
Click OK twice.
6.
To configure the Autodesk control surface on Linux-based workstations:
On the Lustre workstation, use a text editor such as nedit to configure the network port
connected to the control surface with an unrelated static IP address that does not interfere
with any of the IP addresses on the network. Also assign an appropriate subnet mask. Type:
nedit /etc/sysconfig/network-scripts/ifcfg-eth<port#>
Modify the IPADDR and NETMASK values. For example:
IPADDR=192.168.125.10
NETMASK=255.255.255.0