SEBU8387
Illustration 52
Typical example
3. Install a suitable tube onto the drain (1). Open the
drain (1). Allow the fluid to drain into the container.
Remove the tube.
4. Tighten the drain (1) by hand pressure only.
5. If equipped, remove the wiring harness from the
sensor on the bottom of the bowl (3).
Fuel System Primary Filter (Water Separator) Element - Replace
g01370515
Illustration 53
Typical example
6. Rotate the bowl (3) counterclockwise in order to
remove the bowl. Remove the O ring seal (2).
Clean the bowl.
77