Technical Details/Regulations - Bellfires HORIZON BELL XXL Installation Instructions And Instructions For Use

Table of Contents

Advertisement

Bellfi res
8

TECHNICAL DETAILS/REGULATIONS

National installation regulations:
Gas safety installation and use regulations 1984 plus all relevant
safety and building regulations concerning fi re installation
Model
Country
Product identifi cation no
Type of appliance under CE-norm
Category of appliance
Nominal heat input (Gross calorifi c value) : 16.0 kW
Nominal heat output
Effi ciency class
NOx-class
Gas rate (max.)
Supply pressure
Burner pressure (max.) Hot
Burner pressure (max.) Cold
Burner pressure (min.)
Gas regulator block (hand control)
Gas regulator block (remote control)
Main burner
Primary air inlet main burner
Main burner injector
Pilot light burner
Pilot light burner injector
Gas connection
Concentric fl ue system connection
Batteries remote control
- Receiver
- Hand-transmitter
(*)
: When the appliance has reached its thermal equilibrium.
(**) : Burner at maximum. Appliance is cold.
Flue gas exhaust and combustion air supply:
Roof-mounted outlet : Barbas concentric fl ue system Ø100 mm - Ø150 mm. Rigid and/or fl exible.
Horizontal wall outlet : Barbas concentric fl ue system Ø130 mm - Ø200 mm. Rigid. With wall outlet
Heat changing surface: Entire front of the appliance.
Instructions for use and installation instructions
: HORIZON BELL XXL
: GB; Great Britain/IE; Ireland
: 0063BT3024
: C
/ C
11
: I
natural gas G20
2H
: 12.0 kW
: 2 (75%)
: 5
: 1.50 m
: 20.0 mbar
: 11.0 mbar(*)
: 10.3 mbar(**)
: 3.5 mbar
: BM 733-234484
: Mertik GV 34 / GV 60
: IGP 1617x140 mm Natural gas : IGP 1617x140 mm Butane/Propane
: 1x Ø15.0 mm
: no 400
(= 1x Ø4.00 mm)
: SIT 0.145.019
: no 37 (SIT 0.977.132)
: 3/8" G / Ø12 mm
: Ø130 mm - Ø200 mm
: 4x 1.5V AA
: 1x 9V block
Ø130 mm - Ø200 mm.
/ C
31
31S
3
/hr.
s
English
: GB; Great Britain/IE; Ireland
: 0063BT3024
: C
/ C
/ C
11
31
31S
: I
butane/propane G30/G31
3B/P
: Butane (G30) : 13.8 kW
Propane (G31): 12.0 kW
: 8.2 - 9.3 kW
: 2 (76%)
: 5
: Butane (G30) : 1020 gr/hr.
Propane (G31): 860 gr/hr.
: Butane (G30) : 37.0 mbar
Propane (G31): 37.0 mbar
: 29.0 mbar
: 29.0 mbar
: 5.0 mbar
: BM 733-234484
: Mertik GV 34 / GV 60
: 2x Ø20.0 mm
: no 18 / 380
(= 7x Ø0.71 mm)
: SIT 0.145.019
: no 23 (SIT 0.977.150)
: 3/8" G / Ø12 mm
: Ø130 mm - Ø200 mm
: 4x 1.5V AA
: 1x 9V block
71

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents