Installation Instructions - Bellfires HORIZON BELL XXL Installation Instructions And Instructions For Use

Table of Contents

Advertisement

Bellfi res
3

INSTALLATION INSTRUCTIONS

3.1 GENERAL
The gas fi re must be positioned and connected as a "room sealed system" (balance
fl ue) appliance by a "Gas Safe Register" registered gas installation engineer in accor-
dance with the following installation instructions, nationally and locally applicable
regulations (see "Technical Details/ Regulations" at the rear of this manual). If you have
any queries regarding the installation, please consult your local gas company.
Important:
Before beginning the installation, check that the details on the
rating plate correspond to the gas type and pressure to which
the appliance will be connected.
The appliance is factory set to the correct nominal heat input. The pilot light is set to the
correct level of consumption.
It is possible to install the gas fi re with either a wall or roof outlet.
The roof connection must be carried out using the Barbas concentric fl ue system
Ø100 mm - Ø150 mm. The fumes are exhausted naturally to the outside environment
through the inner Ø100 mm pipe whereas the combustion air supply passes between
the Ø100 mm and Ø150 mm pipes.
The wall connection must be carried out using the Barbas concentric fl ue system
Ø130 mm - Ø200 mm. The fl ue gases are evacuated outside by means of natural draft
through the internal pipe of Ø130 mm, whereas the combustion air is supplied between
the pipes of Ø130 mm and Ø200 mm.
The wall outlet
itself is, depending on the concentric fl ue gas system confi guration,
Ø100 mm - Ø150 mm or Ø130 mm - Ø200 mm.
The gas fi re can be installed in a completely sealed or mechanically ventilated house
without extra ventilation and/or fume extraction.
The gas fi re can be installed as an insertion into an existing open fi re place or as
a built-in appliance in a new fi re place.
In order to prevent the fi replace heating up excessively, it must be properly
ventilated by installing vents at the top and bottom of the fi replace.
The appliance can be fi tted with a convection package as an optional extra. This is a
"convection jacket" for around (or above) the appliance, two fl exible aluminium pipes
and two built-in convection vents. This enables hot air to be circulated into the room.