R O B E R T S
G O R D O N
Wire-nut the wires together
Gnd.
Conduit Hole
Figure 31a. Electrical Connection to the Burner Box using Line Voltage Thermostat on Control
Wire-nut the wires together
Gnd.
Figure 31b. Electrical Connection to the Burner Box with Optional External Low Voltage Thermostat
FOR EXTERNAL THERMOSTAT CONNECTION:
Run 2 wires from low voltage thermostat through conduit as shown. The purple wire from the valve and the blue wire from
the transformer have 1/4" (6 mm) blade female electrical terminals, which are connected by a black jumper wire. Cut the
female connections off the ends of the blue and purple wires and strip the ends approximately 1/2" (1.3 cm). Connect
these 2 wires to the thermostat wires using suitable wire connectors.
L1
Green to Gnd.
L2
White to L2
Black to L1
Liquid Tight
Conduit Connector
Green White Black
Green to Gnd.
White to L2
Black to L1
Blue to transformer
L1
Purple
L2
Blue
From External Thermostat
Conduit Hole
Liquid Tight
Conduit Connector
White
Green
Black
Internal Wire Bundle
Purple to valve
1 0 :
S E C T I O N
W I R I N G
Internal Wire Bundle
Burner Box
Liquid Tight Flexible
Conduit for Outdoor Use
or Equivalent
Burner Box
Liquid Tight Flexible
Conduit for Outdoor Use
or Equivalent