The Handy THSSALT Operator's Manual And Parts List page 10

Salt spreader
Hide thumbs Also See for THSSALT:
Table of Contents

Advertisement

STEP 3: Connecting the Solid Linkage
1. Push the flow control handle to the "30" position. Insert the "A" end of the connecting rod (#34)
through the Ø8 flat washer (#12) and into the hole on the gauge level plate (#46). Secure with an
M8 lock nut (#11).
2. Insert the "B" end of the connecting rod (#34) through the Ø8 flat washer (#12) and into the hole on
the fixed plate (#13). Secure with an M8 lock nut (#11).
3. Push the control handle to the "0" position. The hole in the bottom of the spreader should be
completely closed. If the flow control handle position and the hole in the bottom of the hopper does
not match exactly, loosen the two bottom M6 lock nuts (#9) and move the gauge level plate until
the handle position and the hole in the bottom of the hopper match. Re-tighten the two M6 lock
nuts (#9).