With reference to the above diagram, the minimum safe distances from heat sensitive or inflammable materials,
such as load bearing and other walls are:
A
20 cm. from the wall behind the stove
B
20 cm. from the side wall
C
100cm. in the radiating area
In the case of flooring that is heat sensitive or inflammable the floor should be protected (using for example sheets
of steel plate, marble or tiles). The minimum distances are:
D
50 cm.
E
30 cm. (measured from the internal corner of the door opening)
In general
Ensure that there is adequate ventilation in the room where the stove is to be installed (see section "1.3 External
air intake").
Keep any inflammable product well away from the stove while it is lit (MINIMUM: 100 cm. from the front wall).
The door must remain closed while the stove is operating, otherwise you could damage the inside of the fire
chamber.
36
6 MINIMUM SAFETY DISTANCE
Radiating zone
Rear wall
A
Stove
Floor protection