INSTALLATION INSTRUCTIONS
3. Connective Pipe and Drainage
Installation
Drainage
1. Run the drain hose sloping downward.
Do not install the drain hose as
illustrated in Fig.7.
2. When connecting extension drain hose,
insulate the connecting part of extension
drain hose with a shield pipe, do not let
the drain hose slack.
Connective pipe installation
1. For the left-hand and right-hand piping,
remove the pipe cover from the side
panel.
2. For the rear-right-hand and rear-left-hand
piping, install the piping as shown.
3. Fix the end of the connective pipe. (Refer
to Tightening Connection in
REFRIGERANT PIPING CONNECTION)
4. Indoor unit installation
1. Pass the piping through the hole in the
wall.
2. Put the upper claw at the back of the
indoor unit on the upper hook of the
installation plate, move the indoor unit
from side to side to see that it is securely
hooked (see Fig.10 & Fig.11).
3. Piping can easily be made by lifting the
indoor unit with a cushioning material
between the indoor unit and the wall.
Get it out after finish piping.
4. Push the lower part of the indoor unit up
on the wall, then move the indoor unit
from side to side, up and down to check
if it is hooked securely.
Do not block water flow by a rise.
Right-hand piping
Left-hand piping
Fig.8
6
Do not put the end of
drain hose into water.
Fig.7
Rear-right piping
Rear-left piping
Fig.9
Upper Hook
Lower Hook
Fig.10
Cushioning
material
Fig.11

Hide quick links: