Low Voltage Cables; Gas Heater Connections - Compool Cp3810 Installation & Operating Instructions Manual

Aquatic control system
Table of Contents

Advertisement

Compool Cp3810

Low Voltage Cables

Control Panel
6-conductor cable runs between the Control Panel and the Power Center.
Heater Connection
2-conductor cable runs between the heater and the Power Center.
Water Temperature Sensor
2-conductor cable runs between the Water Temperature Sensor and the Power Center.
Freeze Temperature Sensor
2-conductor runs between the Freeze Temperature Sensor and the Power Center.
Caution Do not install low voltage and high voltage wires in the same conduit. Use conduit
when cable goes underground.

Gas Heater Connections

The diagram above shows how to wire a gas heater.
To wire the gas heater
1.
2.
3.
4.
Run a 2-conductor cable from the heater to the Power Center.
At the heater, connect 2-conductor cable as instructed in heater installation manual.
At the Power Center circuit board, connect 2-conductor cable to the HTR terminals.
If heater has electronic ignition, provide high voltage power from the Sub-panel.
HEATER
ON
OFF
PRESSURE
LIMIT
THERMOSTAT
13