Sun Enterprise Systems; Preparing For A Sun Storedge A5X00 Installation - Sun Microsystems Sun StorEdge Installation Manual

Pci dual fibre channel host adapter
Hide thumbs Also See for Sun StorEdge:
Table of Contents

Advertisement

Sun Enterprise Systems

The Sun StorEdge PCI Dual Fibre Channel Host Adapter does not support JTAG.
When you install the PCI host adapter in a Sun Enterprise™ system, be sure that the
corresponding PCI riser card has the JTAG jumper removed (FIGURE 1-1).
Note – If the JTAG jumper is installed, the PCI I/O board will not be recognized or
initialized during POST (power-on self-test) nor will it subsequently be recognized
by the operating system.
JTAG Jumper
FIGURE 1-1

Preparing for a Sun StorEdge A5x00 Installation

1. Use the array's front panel module (FPM) to ensure that the firmware level of the
interface boards is at least 1.05.
4
Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007