  • Page 1: Installation Guide

    Sun StorEdge ™ PCI Dual Fibre Channel Host Adapter Installation Guide Sun Microsystems, Inc. www.sun.com Part No. 806-4199-12 January 2007, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback...
  • Page 2 Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, Californie 95054, Etats-Unis. Tous droits réservés. Sun Microsystems, Inc. a les droits de propriété intellectuels relatants à la technologie qui est décrit dans ce document. En particulier, et sans la limitation, ces droits de propriété...
  • Page 3: Table Of Contents

    Device Drivers 1 SunVTS qlctest 2 Tools and Equipment Needed 3 Preparing for Installation 3 Sun Enterprise Systems 4 Preparing for a Sun StorEdge A5x00 Installation 4 Installing the Host Adapter 7 Testing the Installation 12 SunVTS 12 Testing Procedure 12...
  • Page 4 Performance Specifications 16 Power Requirements 16 Physical Dimensions 17 Regulatory Compliance 17 PCI Edge Connector Pin Definitions: 32-Bit Cards 18 PCI Edge Connector Pin Definitions: 64-Bit Cards 20 Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007...
  • Page 5: Preface

    Preface The Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide describes how to install Sun StorEdge™ PCI Dual Fibre Channel Host Adapters. These instructions are designed for an experienced system administrator or trained service provider. Using UNIX Commands ®...
  • Page 6: Typographic Conventions

    Shell Prompts TABLE P-2 Shell Prompt C shell machine_name% C shell superuser machine_name# Bourne shell and Korn shell Bourne shell and Korn shell superuser vi Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007...
  • Page 7: Related Documentation

    SunVTS 4.0 Test Reference Manual 806-2058 Sun Enterprise™ Systems PCI I/O Board Installation and Component 805-1372 Replacement Sun StorEdge Disk Arrays Sun StorEdge A5000 Hardware 805-0264 Configuration Guide Accessing Sun Documentation Online The docs.sun.com web site enables you to access Sun technical documentation on the Web.
  • Page 8 Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007...
  • Page 9: Declaration Of Conformity

    Compliance Model Number: DualPCI (FC0610404) Product Family Name: Sun StorEdge 1GB PCI Dual Fibre Channel Host Adapter (X6727A) USA - FCC Class B This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This equipment may not cause harmful interference.
  • Page 11: Regulatory Compliance Statements

    FCC radio frequency emission limits. Networking connections can be made using unshielded twisted-pair (UTP) cables. Modifications: Any modifications made to this device that are not approved by Sun Microsystems, Inc. may void the authority granted to the user by the FCC to operate this equipment.
  • Page 12 ICES-003 Class B Notice - Avis NMB-003, Classe B This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007...
  • Page 13: Safety Agency Compliance Statements

    Follow all cautions and instructions marked on the ■ Do not make mechanical or electrical modifications to the equipment. equipment. Sun Microsystems is not responsible for Ensure that the voltage and frequency of your power ■ regulatory compliance of a modified Sun product.
  • Page 14: Power Cord Connection

    Laser Compliance Notice Sun products that use laser technology comply with Class 1 laser requirements. Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007...
  • Page 15 Nehmen Sie keine mechanischen oder elektrischen Stecken Sie auf keinen Fall irgendwelche Gegenstände ■ Änderungen an den Geräten vor. Sun Microsystems, in Öffnungen in den Geräten. Leitfähige Gegenstände könnten aufgrund der möglicherweise vorliegenden übernimmt bei einem Sun-Produkt, das geändert wurde, gefährlichen...
  • Page 16 Stromschlags zu reduzieren, schließen Sie das Gehäuseabdeckung Kabel nur an eine fachgerecht verlegte, geerdete Steckdose an. Sie müssen die obere Abdeckung Ihres Sun-Systems entfernen, um interne Komponenten wie Karten, Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007...
  • Page 17 Ne pas apporter de modification mécanique ou électrique Ne jamais introduire d’objets quels qu’ils soient dans ■ au matériel. Sun Microsystems n’est pas responsable de la une des ouvertures de l’appareil. Vous pourriez vous conformité réglementaire d’un produit Sun qui a été...
  • Page 18 Elles risquent d’exploser en cas de mauvais traitement. Ne pas jeter la batterie au feu. Ne pas la démonter ni tenter de la recharger. xviii Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007...
  • Page 19 Ne remplacez ce bloc que par un bloc-batterie Sun Microsystems du même type. Ne le démontez pas et n’essayez pas de Normativas de seguridad le recharger hors du système. Ne faites pas El siguiente texto incluye las medidas de seguridad que se brûler la batterie mais mettez-la au rebut...
  • Page 20 Precaución – De acuerdo con la norma DIN 45 635, Parte 1000, se admite un nivel de presión acústica para puestos de trabajo máximo de 70Db(A). Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007...
  • Page 21 Las pilas sólo deben sustituirse por el mismo tipo de paquete de pilas de Sun Microsystems. No las desmonte ni intente recargarlas fuera del sistema. No arroje las pilas al fuego. Deséchelas siguiendo el método indicado por las disposiciones...
  • Page 22 Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007...
  • Page 23: Installation

    C H A P T E R Installation This chapter describes how to install the Sun StorEdge™ PCI Dual Fibre Channel Host Adapter in a system. Software Requirements Please consult the most resent version of the Release Notes for the lastest updates on the Operating Systems, platforms, software and storage devices supported.
  • Page 24: Sunvts Qlctest

    SunVTS must already be installed before you can do a pkgadd of the qlctest. ■ Release Notes are included in the SUNWvtsqc package. ■ qlctest Dependencies TABLE 1-3 SunVTS Release qlctest Package SUNWvtsqc SUNWvtsqc Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007...
  • Page 25: Tools And Equipment Needed

    Tools and Equipment Needed You may need to order fiber optic cables. You can order them in the following lengths: 2-meter, part number X973A ■ 15-meter, part number X978A ■ You will also need: A No. 2 Phillips screwdriver ■ An antistatic wrist strap ■...
  • Page 26: Sun Enterprise Systems

    Sun Enterprise Systems The Sun StorEdge PCI Dual Fibre Channel Host Adapter does not support JTAG. When you install the PCI host adapter in a Sun Enterprise™ system, be sure that the corresponding PCI riser card has the JTAG jumper removed (FIGURE 1-1).
  • Page 27 If the firmware level is less than 1.05, you must upgrade the firmware using an S-Bus-based host system before you can connect the array to the Sun StorEdge PCI Dual Fibre Channel Host Adapter. The instructions for obtaining the upgrade patch are in Step 3.
  • Page 28 10. For systems with a standby-type power switch, disconnect the power cord. Standby-type power switches have a icon. 11. Open the system. Refer to your system documentation for specific instructions. Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007...
  • Page 29: Installing The Host Adapter

    1. Pull the two dust covers out of the 1x9 optical transceiver (OT) connectors (FIGURE 1-3). Sun StorEdge PCI Dual Fibre Channel Host Adapter Dust Covers FIGURE 1-3 2. Install the host adapter in the PCI slot you have chosen.
  • Page 30 Caution – In multiple-initiator configurations: • When a Sun StorEdge PCI Dual Fibre Channel Host Adapter is directly connected to a Sun StorEdge A5x00, each port on the host adapter must be connected to a separate loop on the A5x00.
  • Page 31 7. Power on your peripherals and then your system. Note – If your system starts to reboot, interrupt the reboot process by pressing the Stop-A keys. The system should now be at the ok prompt. If a > prompt is showing, type n to switch to the ok prompt.
  • Page 32 /pci@f,4000/SUNW,isptwo@3 /pci@f,4000/SUNW,isptwo@3/st /pci@f,4000/SUNW,isptwo@3/sd /fhc@e,f8800000/sbus-speed@0,500000 /fhc@e,f8800000/eeprom@0,300000 /fhc@e,f8800000/flashprom@0,0 /fhc@e,f8800000/environment@0,400000 /fhc@e,f8800000/ac@0,1000000 /pci@e,2000/pci@2 /pci@e,2000/pci@2/SUNW,qlc@5 /pci@e,2000/pci@2/SUNW,qlc@4 /pci@e,2000/pci@2/SUNW,qlc@5/fp@0,0 /pci@e,2000/pci@2/SUNW,qlc@5/fp@0,0/disk /pci@e,2000/pci@2/SUNW,qlc@4/fp@0,0 /pci@e,2000/pci@2/SUNW,qlc@4/fp@0,0/disk System Recognition of the Host Adapter, Method A, Part 1 FIGURE 1-5 Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007...
  • Page 33 System Recognition of the Host Adapter, Method A, Part 2 FIGURE 1-6 In FIGURE 1-6, /pci@1f,0/pci@1/pc1@1/SUNW,qlc@4 is one port on the Sun StorEdge PCI Dual Fibre Channel Host Adapter and the disks are in a Sun StorEdge A5000 array (SENA). ok select /pci@e,2000/pci@2/SUNW,qlc@5...
  • Page 34: Testing The Installation

    Select devices None and select intervention. b. Select mode Functional test. c. Select HostAdapters qlcx where x is the qlc # of the qlc port you want to run this test against. Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007...
  • Page 35 d. If you want to run the external loopback test, place a loopback plug into the qlc port that you want to test. If you do not have an external loopback plug, you can make one by taking apart a fiber cable and plug the same cable into the transmitter and receiver of the qlc port.
  • Page 36 Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007...
  • Page 37: Specifications

    A P P E N D I X Specifications PCI Card The Sun StorEdge PCI Dual Fibre Channel Host Adapter is a Fibre Channel PCI card with two onboard optical transceivers. This host adapter is PCI Version 2.1 compliant. Fibre Channel Interface Specifications...
  • Page 38: Performance Specifications

    Capacitance per PCI signal line IDSEL ≤8 pF FC-AL Interface 1 Gbit optical (1.026 bits/sec) Power Requirements Power Requirements TABLE A-3 Specification Rating Voltage and current 5V 5%,3A Ripple 100 mV Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007...
  • Page 39: Physical Dimensions

    Physical Dimensions Physical Dimensions TABLE A-4 Height Width Depth Weight 15 mm 106.68 mm 174.63 mm 170.1 g 0.6 in. 4.2 in. 6.875 in. 6.0 oz. Regulatory Compliance Requirements Met or Exceeded by the Host Adapter TABLE A-5 Category Rating Safety UL 1950 CSA 950...
  • Page 40: Pci Edge Connector Pin Definitions: 32-Bit Cards

    KEYWAY RESERVED +3.3V AD08 GND (PRSNT2) AD17 AD07 KEYWAY C_BE2 +3.3V KEYWAY AD05 RESERVED IRDY AD03 +3.3V DEVSEL AD01 LOCK ACK64 +3V/+5V PERR AD31 +3.3V AD29 SERR Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007...
  • Page 41 PCI Edge Connector Pin Definitions, 32-Bit Cards(Bottom) TABLE A-7 Description Description Description TRST AD28 +12V AD26 AD15 +3.3V AD24 AD13 IDSEL AD11 INTA +3.3V INTC AD22 AD09 AD20 KEYWAY RESERVED KEYWAY AD18 C_BE0 RESERVED AD16 +3.3V KEYWAY +3.3V AD06 KEYWAY FRAME AD04 RESERVED...
  • Page 42: Pci Edge Connector Pin Definitions: 64-Bit Cards

    PME# C/BE[1]# AD[15] AD[31] AD[30] ad[14] +3.3V AD[29] +3.3V Ground AD[13] Ground AD[28] AD[12] AD[11] AD[27] AD[26] AD[10] Ground AD[25] Ground M66EN AD[09] +3.3V AD[24] Keyway Keyway Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007...
  • Page 43 PCI Expansion Board Pinout—Universal Board TABLE A-9 Side B Side A Side B Side A Keyway Keyway Ground AD[52] AD[08] C/BE[0]# AD[51] AD[50] AD[07] +3.3V AD[49] Ground +3.3V AD[06]# AD[48] AD[05] AD[04]# AD[47] AD[46] AD[03] Ground AD[45] Ground Ground AD[02] Ground AD[44] AD[01]...
  • Page 44 Sun StorEdge PCI Dual Fibre Channel Host Adapter Installation Guide • January 2007...