The low carbon dryer

Advertisement

INSTALLATION AND SERVICE INSTRUCTIONS
Keep this booklet for future reference.
The dryer must be fitted by a competent person. In the U.K. Registered Installers undertake to
work to safe and satisfactory standards.
The dryer must be installed in accordance with the Gas Safety (Installation and Use)
Regulations 1998.
Guidance may be obtained from the relevant parts of B.S. 7624: B.S. 5440 parts 1 and 2, B.S.
6891: current editions, I.E.E. Wiring Regulations, and relevant Building Regulations.
Failure to install the appliance correctly could invalidate the warranty liability claims and could
lead to prosecution.
FOR USE IN THE UNITED KINGDOM AND IRELAND WITH
NATURAL GAS ONLY : I
, GAS SUPPLY PRESSURE : 20 mbar.
H
2
THE INSTALLER MUST LEAVE THIS BOOKLET WITH THE
CUSTOMER

Advertisement

loading
Need help?

Need help?

Do you have a question about the eco 43a the low carbon and is the answer not in the manual?

Questions and answers

Summary of Contents for White Knight eco 43a the low carbon

  • Page 1 INSTALLATION AND SERVICE INSTRUCTIONS Keep this booklet for future reference. The dryer must be fitted by a competent person. In the U.K. Registered Installers undertake to work to safe and satisfactory standards. The dryer must be installed in accordance with the Gas Safety (Installation and Use) Regulations 1998.
  • Page 2: Table Of Contents

    Contents Page Technical Data ..... . 3 Installation ......4 Service instructions .
  • Page 3: Technical Data

    TECHNICAL DATA CONTROL Type:Pactrol full sequence flame control, P16AGTD(CE) GENERAL 414601. Ignition electrode gap to burner 3 to 4mm Flame failure electrode (4213 078 52641).Height from heater Front loading tumble dryer with gas heating. Reverse base to centre of electrode 27.0±0.5mm. action drum tumble.Time control.
  • Page 4: Installation

    INSTALLATION 5 POSITION OF DRYER AND CONNECTIONS 1INSTALLATION The dryer is designed for installation using a flexible gas connection with tubing in accordance with B.S.669. Ensure that the supply gas sizing is adequate. When installing, position the appliance so that the plug is accessible.
  • Page 5 9 STACKING 6. OPERATIONAL CHECK Instructions for stacking, if required, are supplied 6.1 Remove the pressure test point screw from the gas with the stacking kit. tee connection at the back of the dryer and connect a gas pressure gauge. PROGRAMME 6.2 Check that the dryer timer is in the 'off' position, and that the heat switch is set to 'high'.
  • Page 6: Service Instructions

    SERVICE INSTRUCTIONS RECOMMENDATIONS FOR DISMANTLING Note:Re-assembly should be done in reverse sequence to these instructions. Terminal Block (28),Control Unit (10),Timer (211), Heat Switch (235),Neon (213),Micro-Switch Assembly (248),Control Panel (353). Withdraw 3 screws from the back flange of the Table Top Assy.(386) and lift and move it rearwards for removal.
  • Page 7 Withdraw the 3-screws and shakeproof washers (13) Withdraw the 8-screws securing the Back Panel (24) to securing the Flame Tube Assy.(34) to the Cabinet Base. the Cabinet (196).Disengage the T-piece Grommet from Note:On re-assembly the shakeproof washers must be the slot in the Back Panel and lift off. replaced to ensure a good earth connection.
  • Page 8: Fault Finding

    FAULT FINDING In the event of an electrical fault carry out the preliminary electrical system checks i.e. earth continuity, polarity, and resistance to earth. Use each chart to locate the fault causing the dryer to operate incorrectly as follows: Chart No: 1 Motor does not run.
  • Page 9 Chart 2. Motor runs but full sequence control does not produce ignition spark With timer ON (30 min) is voltage between output C2 on timer and START TB-N 230v?? Exchange timer. Does control spark? Does control spark with high heat selected? Does control spark with low heat selected?
  • Page 10 Chart 3. Motor runs Full Sequence Control produces ignition sparks, but gas does not ignite. Start Remove plinth 199. Can gas be lit manually? Check spark gap continuity of Whilst control is sparking is H.T. lead and electrode not voltage at terminal 4 of control cracked.
  • Page 11 Chart 4. Motor runs, gas ignites but stays on for only short period Before proceeding, ensure polarity of 13Amp supply socket and earthing is correct Is weight of load suitable? Is Start filter clean? Is vent hose or terminal unobstructed? Is vent terminal unaffected by wind conditions that may cause back pressure?
  • Page 12: Wiring Diagram

    WHITE KNIGHT ECO 43A_ CROSSLEE P.L.C.
  • Page 13: Exploded Views

    WHITE KNIGHT ECO 43A CROSSLEE p.l.c. EXPLODED VIEW 1 249a 249b 203a...
  • Page 14 WHITE KNIGHT ECO 43A CROSSLEE P.L.C. EXPLODED VIEW 2 REAR ASSEMBLY VIEWED FROM FRONT...
  • Page 15 WHITE KNIGHT ECO 43A_ CROSSLEE P.L.C. EXPLODED VIEW 3 INTERNALS VIEWED FROM REAR...
  • Page 16 WHITE KNIGHT ECO 43A_ CROSSLEE P.L.C. EXPLODED VIEW 4 INTERNALS VIEWED FROM REAR 101a...
  • Page 17 White Knight ECO43A_ Crosslee plc Exploded View 5...
  • Page 18: Parts List

    BG43A_ PARTS LIST Item Description Part Number Expl. View Control Unit 4213 092 25451 Control Unit Bracket Assembly 4213 070 08623 Screw M4 x 10 8213 130 37161 2,3&5 Rear Seal Assembly 4213 092 08511 External Feed Pipe (Bundy Tube Assy 3) 4213 089 0788_ Gas Inlet Connector 4213 078 49504...
  • Page 19 BG43A_ PARTS LIST 6G*3/8 DP/PWABE/NIBS/TSZPC 8213 130 38051 8Gx1 P/F AB S/TS MECH ZPC 8213 130 38101 Hinge Assembly 4213 092 26071 Window 4213 077 4409_ Door Frame (Mid White) 4213 077 92271 Latch Pivot 4213 075 13013 Latch Spring 4213 075 70833 Door Latch 4213 077 53413...
  • Page 20 BG43A_ PARTS LIST Bearing Pads & Brush Seal Kit 4213 092 21171 Manufactured by: Crosslee plc. Lightcliffe Factory, Hipperholme, Halifax, West Yorkshire, HX3 8DE ECO 43A_ Installation/Service Book 4213 094 79351...