Rcom USB 20 User Manual page 9

Digital egg incubator
Table of Contents

Advertisement

SET UP(Other Functions)
T.CAL
Temperature
Calibration
H.CAL
Humidity
Calibration
Abnomal
High Alarm
Abnomal
low Alarm
Factory setting
Easy Function Operation
Function
Automatic Mode
Incubation
Other(Manual) Mode
Incubation
How to change Setting
under Incubation
Incubation
Termination
Incubator Initialization
(Factory Setting)
How to change
How to turn off
Humidification Function
In case of low humidity
incubation
Egg Turning Test
1. Introduction
WARNING
Fatal Damage
with Incorrect Calibration
WARNING
Fatal Damage
with Incorrect Calibration
Alarm sounds when incubator temp. is higher than setting value
because of room temp. change or heating system disorder
* Setting Range : 0.0
Alarm sounds when incubator temp. is lower than setting value
because of room temp. change or heating system disorder
* Setting Range : 0.0
Selecting Centigrade (
* Default Value : Centigrade (
LCD Backlight management setting
* Always On : Always BackLight On
* Event On
: 20 Sec. ON with Key input
ON/OFF Setting for Melody, other alarms
* Default Value : ON
It returns to factory setting when you change the initial setting at discretion.
Basic information of Incubator (versoin Indication)
If you want to change setting value, keep pressing "SET" button and change the value.
Select
the Species of Bird
Select
the Species of Bird
Once: Temp. Setting
4 times: Humidity Setting
7 times:
Egg Turning Angle Setting
9 times: Egg Turning Interval Setting
Screen
System finish
on Incubation
Are you sure?
"All Reset"
Screen
on Incubation
UNDER 30%
Setting Value
5 Sec.
(6) SET UP(Other Functions) /
Push SET UP key and then select each function icon using
Be sure to read CAUTIONS. We do no recommend customers
to recalibrate by their own. If you need to recalibrate, please
ask purchase place.
Be sure to read CAUTIONS. We do no recommend customers
to recalibrate by their own. If you need to recalibrate, please
ask purchase place.
~ 5.0
(Default Setting : 2.0 )
~ -5.0
(Default Setting : -3.0 )
o
o
C) and Fahrenheit (
F)
o
C)
* Always Off : Always BackLight Off
* Default Value : Always On
put some water after take off label from the back and attach to the window.
2 Sec.
Temp. Setting
Humid. Setting
Egg Turning Angle Setting
Egg Turning Interval Setting(Incubation day)
Select YES
"OFF"
Check
Easy Function Operation
UP/DOWN key(ENTER)

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the USB 20 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Usb 50Pro 20

Table of Contents