Wiring The Fan - Quadra-Fire QVI-25FB Installer's Manual

Hide thumbs Also See for QVI-25FB:
Table of Contents

Advertisement

INSERT RELIEF
AROUND CORD IN THIS END
FROM OUTSIDE OF UNIT
FEED PLUG
THROUGH HOLE
Figure 8. Junction box installation
Optional Accessories
Use of the electrical junction box provided is required if
using a blower or remote. Plug the cord into a convenient
outlet. An electrician may install an outlet box inside the
appliance. Place the outlet in the lower, back corner of the
appliance. Make sure fan doesn't touch back wall.
WARNING: USE OF THE CORD SUPPLIED WITH
!
THE ELECTRICAL JUNCTION BOX IS REQUIRED.
Fan Option
This product accepts an optional blower GFK-160A. Instal-
lation of this blower requires 110 VAC power supplied to the
JUNCTION
SPEED CONTROL
BOX
(RHEOSTAT)
REMOTE
FAN
OUTLET
OUTLET
BLK
BLK
BLK
TEMPERATURE
SENSOR SWITCH
Figure 9. Fan Wiring Diagram
16
SIDE
WALL
JUNCTION
BOX
FAN
TEMPERATURE
SENSOR SWITCH
BEND UP
TABS
VARIABLE SPEED CONTROL
JUNCTION BOX
BLK
BLK
Quadra-Fire • QVI-25FB • 2031-900 Rev. F • 9/07
electrical junction box. The optional blower GFK-160A CAN-
NOT be used when using operable glass doors.
On units already installed removal of decorative front, sur-
round and gas insert is required.
• Detach flexible liner from back of unit.
• Remove the four screws on the coverplate (see Figure 10).
• Bend up the tabs on the base pan (see Figure 9).
• Place the blower in between the bend up tabs.
• Install and wire the blower per instructions shipped with
the fan. Refer to Figure 9 for placement of the temp switch
bracket and mounting stud.
• The ground wire of the fan can clip on the side of the
base pan.
• Attach rubber grommets to cover plate as shown (in-
cluded in manual bag assembly).
• Reinstall the cover plate on the unit. Make sure the fan
does not make contact with the back wall.
RUBBER
GROMMETS
Figure 10.
INSERT STUD THROUGH HOLE
AND SECURE WITH WING NUT
REMOTE
RECEPTACLE
BLK
BLK
BLK
WHT
WHT
BLK
GROUND
GRN
WHT
110-120 VAC
FAN
COVER
PLATE
GROUND
WING
NUT
TEMP SWITCH
BRACKET
BLOWER RECEPTACLE
BLOWER
NOTE: If any of the original wire as supplied with the appli-
ance must be replaced, it must be replaced with type 105
crated wire.
NOTE: Do NOT install blower if using operable glass doors.
ATTACH
WIRE
0