External Ports of the 886LCD-M/Flex Motherboard ........24 For System Configurations with 986LCD-M/Flex Motherboard ....... 26 External Ports of the 986LCD-M/Flex Motherboard ........27 Additional Ports for Configurations with Motherboards........30 Power Supply Versions ................... 30 KISS 2U - User’s Manual (Version 1.01)
Page 4
Standard Ports – Pin Assignment ..............56 Serial port COM1 / 2 / 3 (RS232) .................56 Combined PS/2 Keyboard and Mouse Connector..........56 PS/2 Mouse Connector ..................57 PS/2 Keyboard Connector ...................57 Parallel Port (LPT)....................58 VGA Port......................59 USB Port ......................59 KISS 2U - User’s Manual (Version 1.01)
Page 5
Table of Contents Technical Support ..................... 60 Returning Defective Merchandise................ 61 KISS 2U - User’s Manual (Version 1.01)
Computers assumes no liability for printing errors or other inaccuracies in this manual, unless it can be demonstrated that Kontron Embedded Computers is aware of such errors or that Kontron Embedded Computers is unaware of these as a result of gross negligence, and that Kontron Embedded Computers has failed to properly correct the errors or inaccuracies for these reasons.
This symbol refers to general information about the device and the manual. This symbol precedes various product configuration details. This symbol precedes useful hints and tips for everyday use. KISS 2U - User’s Manual (Version 1.01)
Exemption from Liability for Accidents Should the user disregard the instructions (specifically the safety instructions) in this manual and possibly on the device, Kontron Embedded Computers will be exempt from legal liability for accidents. Limitation of Liability / Warranty Obligations...
Take note of the warnings and instructions on the device and in the manual. The KISS 2U platform has been built and tested by Kontron Embedded Computers in accordance with EN 60950/VDE 0805 and left the production plant in a perfectly safe condition.
Page 10
❏ The device should only be operated in a horizontal position. ❏ The device should only be maintained or repaired by specialists authorised by Kontron Embedded Computers, who are aware of the associated dangers. ❏ The device should only be opened for the installation and removal of PCI-/PCIe x16- /PCIe x4 expansion cards, in accordance with the description in this manual.
2. Keep electrostatically sensitive components in their containers, until they arrive at an electrostatically protected workplace. 3. Only touch electrostatically sensitive components when you are properly earthed. 4. Store electrostatically sensitive components in protective packaging or on anti- static mats. KISS 2U - User’s Manual (Version 1.01)
Do not dispose of lithium batteries in general trash collection. Dispose of the battery according to the local regulations dealing with the disposal of these special materials, (e.g. to the collecting points for dispose of batteries). KISS 2U - User’s Manual (Version 1.01)
89/336/EEC in its currently applicable version and/or by German Electromagnetic Compatibility legislation. Should the user make changes and/or add to the device (e.g. installation of expansion cards), the requirements for the EC Declaration of Conformity (protective requirement) may no longer be met. KISS 2U - User’s Manual (Version 1.01)
Optional Components ❏ Slide rails Type Label and Product Identification The type label for the KISS 2U platform is located on the right side of the device. Product Designation Product Identification KISS 2U with PCI-759 SBC card (Single Board Computer)
KISS 2U platform with the necessary characteristics for a computer, which is suitable for use in harsh industrial environments. The KISS 2U platform is available as a 19" rack device and as a desktop version. Versions: KISS 2U Platform Fig.
Page 16
The integrated AC power supply with the power supply On/Off switch is on the back of the device. Fig. 4: KISS 2U platform When switching on the KISS 2U platform, ensure that the ventilation slots are not obstructed. KISS 2U - User’s Manual (Version 1.01)
Product Description Front Side The KISS 2U platform is available as a rackmount version. Fig. 5: Front (rackmount version) with the front access panel closed 1 19" bracket with handle 3 Ventilation grille on the front access panel 2 Light diffusors for HDD and...
Page 18
Product Description The controls (Power On/Off and Reset buttons), USB ports and the integrated 5.25" drive are located on the front of the KISS 2U platform, behind the front access panel. Fig. 7: Front (rackmount version) with the front access panel open 1 Bump stop for the front access 7 1x 5.25"...
Button Reset Button If your system no longer reacts, you need to restart the KISS 2U platform. Press the reset button to restart your system When a reset is performed, all data is erased from the internal memory. The system restarts, without the need to switch the computer off and on again.
“On“. Hard drive activity LED This LED is orange when the hard disk is being (orange) accessed. Do not press the eject button, while the drive LED is lit or flashing. KISS 2U - User’s Manual (Version 1.01)
Product Description Ports on the Front Side USB Ports KISS 2U has two USB (2.0) ports on the front (depending on the system configuration ordered). Various USB-compatible peripherals can be connected to these ports. Fig. 10: USB ports on the front Front Access Panel The front access panel is fitted with a safety lock.
❏ for a 3.5" hot swap module (external accessible) for 2x 2.5“ removable SATA hard disks ❏ for an external accessible slim drive The 3.5” hot swap module allows you to replace the SATA hard disk during operation. KISS 2U - User’s Manual (Version 1.01)
The order or the number of the KISS 2U platform interfaces can be different depending on the device configuration. System Configurations with SBC Cards (PCI-759/-760/-960) Fig. 11: Rear side of the KISS 2U with an SBC card (here with a wide range power supply) 1 Fan of the...
(analog) monitor. USB 2.0 Ports Different USB peripherals can be connected to these ports. LAN Ports These ports are provided as RJ45 connectors with integrated LEDs and support a data transfer rate of 10/100/1000Mbps. KISS 2U - User’s Manual (Version 1.01)
❏ a PS/2 mouse and a PS/2 keyboard (by use of an Y adapter cable only) System Configurations with an 886LCD-M/Flex Motherboard Fig. 13: Rear side of the KISS 2U with an 886LCD-M/Flex (here with a wide range power supply)
10 Line-Out connection (green) 5 Parallel port (LPT) 11 Microphone connection (pink) 6 2x Ethernet ports (RJ45), without integrated LEDs (10/100Mbps) PS/2 Mouse Connector You can connect a PS/2-compatible mouse to the Mini-DIN connector. KISS 2U - User’s Manual (Version 1.01)
Page 27
Two of these ports are provided as RJ45 connectors without integrated LEDs. The third is an Ethernet connection consisting of RJ45 connector with integrated LEDs. All three LAN ports support a data transfer rate of 10/100Mbps. KISS 2U - User’s Manual (Version 1.01)
Product Description For System Configurations with 986LCD-M/Flex Motherboard Fig. 15: Rear Side of the KISS 2U with a 986LCD-M/Flex (here with a wide range power supply unit) Fan of the 6 Ports of the 986LCD-M/Flex Power Supply Unit (PSU) motherboard...
The port is provided as a 9-pin D-SUB connector; it is RS232 configured and allows the connection of a serial peripheral. VGA Port This interface connector is provided as a 15-pin D-SUB socket and allows the connection of an external (analog) monitor. KISS 2U - User’s Manual (Version 1.01)
Page 30
USB 2.0 Ports Different USB peripherals can be connected to these four ports. LAN Ports These ports are provided as RJ45 connectors without integrated LEDs and support a data transfer rate of 10/100/1000Mbps. KISS 2U - User’s Manual (Version 1.01)
Page 31
Line-In Line-In Green Front speaker out Front speaker out Front speaker out Pink Mic-In Mic-In Mic-In Orange Center/Subwoofer Center/Subwoofer Black Rear speaker out Rear speaker out Rear speaker out Gray Side speaker out KISS 2U - User’s Manual (Version 1.01)
Power Supply Versions The power supply unit is located on the rear side of the KISS 2U platform. Every KISS 2U platform can be equipped with either a wide range or a redundant wide range AC power supply unit.
Side View On the left and right sides of the device, there are four M4 threaded screw holes, for installing the KISS 2U platform in a 19" industrial cabinet using slide rails [not included; refer to the chapter “Slide Rails (Option)”.] Fig.
Product Description Integrated Motherboard / SBC Card Depending on the KISS 2U platform configuration ordered, your system may be fitted with a motherboard or an SBC card (Single Board Computer). System Designation Integrated Board Board Type KISS 2U 886LCD-A/B 886LCD-M/Flex...
Product Description Riser Card and/or Backplane and available Bays Depending on the KISS 2U hardware configuration ordered, you can expand you system with full size and/or half size additional cards. When equipping your system with ex pansion cards, pay attention...
2. Turn the device upside down on a table or desk. 3. Remove the protective film fr om the rubber feet. 4. Stick th e four rubber feet to he underside of the device. KISS 2U - User’s Manual (Version 1.01)
Failure to take heed of this warning instruction can result in damage to the device. Please read information provided by the manufacturer of any expansion cards before installing them or removing them from your system. KISS 2U - User’s Manual (Version 1.01)
Page 38
5. Close the device and secure the cover with the knurled screws. Please read information provided by the manufacturer of any expansion cards before installing them or removing them from your system. KISS 2U - User’s Manual (Version 1.01)
The device must only be incorporated and installed by specialists who are qualified in this field. The KISS 2U should be installed in a 19" industrial cabinet using slide rails. Ensure that air flow around the device is adequate when installing the KISS 2U.
Page 40
The voltage feeds must not be overloaded. Adjust the cabling a the external overch arge protection to correspond with the electrical data indicated on the type label. The type label is located on right side of the unit. KISS 2U - User’s Manual (Version 1.01)
AC power socket and power switch Fig. 21: KISS 2U (here with an SBC card and a wide range AC power supply unit) AC power socket and power switch Fig. 21a: KISS 2U (here with a motherboard and a wide range AC power supply unit) To connect the power cable, proceed as follows: 1.
Your computer is fully functional when you turn it on for the first time. If you have ordered your KISS 2U without pre-installed operating system, you have to install the operating system and the corresponding drivers for the ordered computer configuration (optional hardware components).
Maintenance and Prevention Maintenance and Prevention Kontron Embedded Computers systems only require minimal maintenance and care to keep them operating correctly. ❏ Occas ionally wipe the system with a soft dry cloth. ❏ Remove persistent dirt by use of a soft, slightly damp cloth (only use a mild detergent).
2. Loosen the knurled screws (Fig. 22, pos. 2) and pull the handle on the fan slide-in module (Fig. 22, 22b, pos. 5) upwards out of the fan compartment (Fig. 22a, pos. 7). Fig. 22: KISS 2U – Details of the fan slide-in module in the system chassis KISS 2U - User’s Manual (Version 1.01)
Page 45
Maintenance and Prevention Fig. 22a: Fan compartment of the KISS 2U without a fan slide-in module Fig. 22b: Fan slide-in module for the KISS 2U – connector side Key for Figs. 22, 22a and 22b: KISS front access panel 6 Socket for fan control...
Page 46
3. Replace the fan slide-in module with a new functioning one and push it into the system fan compartment until it is attached to the connector. 4. Tighten the knurled screws up again. 5. Close the device and secure the cover with the knurled screws. KISS 2U - User’s Manual (Version 1.01)
❏ If the filter is soiled with greasy dust, you should rinse it with warm water with degreaser added. Do not clean the air filter mat with a piercing jet of water or wring it out. KISS 2U - User’s Manual (Version 1.01)
Page 48
7. Screw the filter mat holder to the chassis using the fixing screw. A defective air filter mat may be replaced only by a Kontron original spare part. ❏ Air filter mat: Part number: 1016-7164 Key for Figs.
Do not dispose of lithium batteries in general trash collection. Dispose of the battery according to the local regulations dealing with the disposal of t hese special materials, (e.g. to the collecting points for dispose of batteries). KISS 2U - User’s Manual (Version 1.01)
Slide Rails (Option) Slide Rails (Option) Kontron stocks slide rails for installing the KISS 2U in an industrial cabinet. These slide rails can be ordered separately. Fig. 25: Attaching the inner section of the slide rails Fig. 25a: KISS 2U platform with slide rails Key for figs.: 25 and 25a:...
❏ 2x bar nut kits ❏ 8x M4x6 flathe ad screws Fig. 26: Installing the “Telescopic Rail” sets Short brackets are generally used at the front of the frame and long brackets at the back. KISS 2U - User’s Manual (Version 1.01)
Slide Rails (Option) Installing the Device in an Industrial Cabinet (using Slide Rails) 1. Ensure that the sides of the KISS 2U chassis are parallel and square to the indust rial cabinet. 2. Use the installation kits and brackets to attach the brackets to the telescopic rails (Fig.
Specification Power specification Power consumption per bay max. 25 W (max. power values (PCI) depending on customer- specific applications) Total consumption of +3.3 280 W VDC and +5 VDC and +12VDC (together) KISS 2U - User’s Manual (Version 1.01)
Technical Data Environmental Specifications x power supply fan entilatio 3x system fan (temperature controlled) 1x CPU fan (for KISS 2U 759-/760-A/B) Passive CPU cooling for: KISS 2U 960-A/B KISS 2U 886LCD-A/B KISS 2U 986LCD-A/B 0 … +50°C / 5–80 % not condensing...
Harmonized Standards Generic emission standard for industrial envi ronments (Emission): EN 61000-6-4:2006 EUROPE Generic standards - Immunity for industrial environments (Immunity): 61000-6-2:2005 U.S.A. FCC 47 CFR Part 15, Class A CANADA ICES-003, Class A KISS 2U - User’s Manual (Version 1.01)
(Data Set Ready) (Request to Send) (Clear t o Send) (Ring Indicator) Combined PS/2 Keyboard and Mouse Connector Sign al Name 6-pin Mini-DIN Connector Keyboard data Mouse data +5 V Keyboard clock Mouse clock KISS 2U - User’s Manual (Version 1.01)
PS/2 Mouse Connector Signal Name 6-pin Mini-DIN Connector Mouse data N.C. +5 V Mouse clock N.C. P /2 K yboard Con nector Signal Name 6-pin Mini-DIN Connector Keyboard data N.C. +5 V Keyboard clock V.C. KISS 2U - User’s Manual (Version 1.01)
Analog green o utput Analog blue output N.C. 5–8 +5 V (DDC) N.C. SDA (DDC) TTL HSync TTL VSync SCL (DDC) USB Port Pin Signal Name 4-pin USB Connector Type A Version 2.0 Data- Data+ KISS 2U - User’s Manual (Version 1.01)
Should you require further information about Kontron Embedded Computers, our products or services, please contact us on the aforementioned telephone and fax bers , or at www.kontron.com...
Where possible, please enclose all the necessary customs documents and invoices. 5. When returning a device: • Pack it securely n its original box. • Enclose a copy of t he RMA form with the consignment. KISS 2U - User’s Manual (Version 1.01)
Need help?
Do you have a question about the Kiss 2U and is the answer not in the manual?
Questions and answers