FLUSHING, CONDITIONING, CLEANING AND SANITIZING PROCEDURES (continued)
B. Reservoir Flushing
WARNING - Failure to follow these
procedures will affect water treatment system
performance and void the warranty.
Clean the inside of the reservoir with a mild soap
solution.
Rinse thoroughly with filtered water.
Mix a solution of 3 ml (1/2 teaspoon) of 5%
sodium hypocholoite to 3.78 liters (one gallon) of
water.
Wipe down the inside of the reservoir with the
solution.
NOTE:
Gloves should be worn during this
procedure.
PARTS - MAINTENANCE - WARRANTY INFORMATION
Filtration Assembly
Major Components
Carbon Filter, 5s
(White Caps)
Carbon Filter, Pb1
(Black Caps)

ROUTINE MAINTENANCE

Service
Requirements
To insure the system operates at its optimum level, certain routine
maintenance must be performed.
Frequency of maintenance performance will depend on feed water
quality and level of system usage.
CLEAN: Each time filters are replaced.
SANITIZE:
At least once a year and each time membrane is
replaced.
PARTS AND SERVICE AVAILABLE THROUGH YOUR OASIS
031666-009 Rev C 2000

SERVICING THE SYSTEM

Component
Routine
Part Number
Maintenance
031829-001
Replace filters as required
or every 6 to 12 months
029924-004
depending on feed water quality
Page 5 of 11
Rinse the reservoir with filtered water.
Completely fill the reservoir with filtered water.
Drain the reservoir through the faucets.
Drain the water from any applicable tanks.
Reservoir is now ready for use.
Recommended
Service Intervals
Replace filters every 6 to 12 months depending on
feed water quality.
®
OASIS
Warranty
System: 5 years limited
See Back Cover for details
®