Advanced Programming
This section enables the installer to program all aspects of
the system. The default options and descriptions of all
programming sections are detailed here.
To access these programming sections, Enter the following
from the Disarmed/Ready state:
Enter:
[*][8][Installer Code][2][Section Number][Data]
[*][8] . . . . . . . . . . .
puts the system in Programming;
[Installer Code] . . .
the default code is [5555]
[2] . . . . . . . . . . . . .
Selects Advanced Programming
[Section Number] .
3 digit code
[Data] . . . . . . . . . .
decimal, hexadecimal data, or tog-
gle ON/OFF
[#] . . . . . . . . . . . . .
exits the programming section
Example: To change the Installer Code from the
default code to '2424', Enter:
[*][8][5555][2][006][2424]
5-1 Section Overview
20