Flash Programming
Flash Programming
Flash Programming provides a quick way to program the system
when standard options are selected or to provide a basic setup
before more advanced programming is performed. Record entry
information in the table provided. Instructions are also provided
on a peel off label on the unit. To enter Flash Programming from
the Ready state enter:
[*] [8] [Installer Code] [1]
Installer Code default is [5555]. See section [006] in
Chapter 5: Advanced Programming to change this
code.
Upon entering Installer's programming, Armed, Ready and Trou-
ble LEDs and the Program icon will flash. There will only be 3
valid keypresses at this time,
[1] to enter Flash Programming,
[2] to enter Advanced Installer's Programming
[#] to exit Installer's Programming.
While in Flash Programming, the Armed, Ready and Trouble
LEDs will be ON. Pressing The Stay key will take the installer to
the next Flash section, and pressing the Away key will take the
installer to the previous Flash section.
Serial Numbers
The first section of Flash Programming is the
area for entering serial numbers. 'Sn00' will
be displayed.
The '1'icon indicates that the system is waiting for the first digit
of a wireless device serial number. For each number that is
entered, the next icon will turn on, until digit '6' is displayed,
and the whole serial number is programmed.
To enter hexadecimal digits, enter [*], digits [1] through
[6] will enter as [A] through [F]. Enter [*] to return to
decimal entry. E.g., To enter SN# 37B007 enter:
[3] [7] [*] [2] [*] [0] [0] [7]
The display will show for 2 seconds what was programmed (Zn
for Zone, and Fb for Wireless key) and which slot (zone or FOB
number) it will occupy. The display will then flash Sn and scroll
through the serial number in groups of 2 digits, indicating
which part of the serial number is displayed by the icons that
are turned on. If the Stay key is pressed during this period, the
system will advance to the next available zone number (or key
fob number) that you can assign to the serial number you have
entered.
Pressing [1] to accept, or [2] to reject a serial number will
return the installer to the beginning of serial number program-
ming until all of the serial numbers have been programmed.
18

Chapter 4: Flash Programming

FLASH
!
!
O P E N
1
2 3 4 5 6 7 8
Memory
AM
Bypass
Fire
Program
PM
Chime
A L A R M
Stay Away
Refer to:Zone Definitions section [ 001] to [004]
Zone Assignment section [202] to [205]
Wireless Serial Numbers in section [804]
Telephone Number
The second section of Flash Programming is
the area for the central station phone num-
ber. 'Ph00' will be displayed.
Entering digits will not move the icon indicator. When the tele-
phone number is entered, pressing [#] or [F] will complete the
entry. The display will then scroll through the phone number in
groups of 2 digits, pause, then restart the phone number. Press
[1] to accept the phone number or [2] to re-enter it.
This section can be manually programmed in Advanced
Programming, section [301]
Account Code
The third section of Flash Programming is
for the account code to the central station.
'Ac00' will be displayed.
Upon entering each digit, the next icon will be on until all 4 dig-
its are programmed and the account code is complete. The dis-
play will then flash 'Ac' and scroll through the account code in
groups of 2 digits, indicating which digits are being displayed by
the icons. Press [1] to accept the code or [2] to re-enter it.
This section can be manually programmed in Advanced
Programming section [310]
Module Placement
The last section of Flash Programming is the
placement testing of the wireless zones.
The display will show 'PLzz' where zz is the
zone number to be tested.
When a zone is violated and restored, there will be 1 bell
squawk for 'Good', and 3 bell squawks for 'bad'. Icon 1 or 3
will turn on to call the latest result. After 3 consecutive Good
results, the zone will be enrolled (corresponding option in sec-
tions [202]-[205] will be enabled), the bell will sound for 2 sec-
onds, and the module placement will go on to the next zone.
Pressing the Stay key will allow you to skip that zone.
When the last zone has tested Good, Flash
Programming is complete, and 'done' will
be displayed.
Enter [#] to return to the beginning of Advanced Program-
ming.. Enter [#] again to exit programming and return to
Ready mode.
To perform this manually, the corresponding zone must
be enabled in sections [202]-[205]. and the Manual
Placement Test in section [904] must be performed.
1
2 3 4 5 6 7 8
O P E N
Memory
AM
Bypass
Fire
Program
PM
Chime
A L A R M
Stay Away
O P E N
1
2 3 4 5 6 7 8
Memory
AM
Bypass
Fire
Program
PM
Chime
Stay Away
A L A R M
O P E N
1
2 3 4 5 6 7 8
Memory
AM
Bypass
Fire
Program
PM
Chime
A L A R M
Stay Away
1
2 3 4 5 6 7 8
O P E N
Memory
AM
Bypass
Fire
Program
PM
Chime
A L A R M
Stay Away

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents