Technical Specifications

Environmental
Security
Mains Supply:
PCB Power Supply:
Standby Battery:
Charging limit:
Recharge time:
Interconnections:
Zones:
Network 1:
Network 2
Additional ports:
Relay Outputs:
Transistor Outputs:
Digi Outputs 1-8:
REN Value:
Speaker Output:
Bell Trigger:
Strobe Trigger:
Mains Input Fuse:
Dimensions:

4. TECHNICAL DESCRIPTION

EN50130-5:1998, Class II
PD6662: 2004, EN50131-1:2006, TS50131-
3:2003, EN50131-6:1997, Grade 1, or 2. See page
19. DD243:2004.
145mA @ 230Vac±10%, 50Hz
13.65VDC, 1.5A. Type A.
A maximum of 500mA is available for the control
unit PCB and other devices (excluding battery
recharge)
12VDC, lead-acid. See page 19 for further details.
750mA
24 hrs max. for 17AH battery
"Specific Wired"
8 on-board zones, expandable to 40
Max of 4 keypads/LEC2s
Max of 3 MSNodes/MRNodes/MSPSUNodes,
or 4 keypads/LEC2s,
Engineer's keypad port
USB port to PC
PSTN/RJ11 for phone connection
1 voltage-free changeover
1A max @ 24Vac or 24Vdc
1 Switched -ve @500mA
1 Switched +ve @500mA
Source 5mA in 12V condition
Sink 100mA in 0V condition
Selectable output sense
0.2
16 Ohms
Switched -ve @500mA
Switched -ve @500mA
T315mA 250V 20mm
384(W), 312(H), 95(D) mm