Clearances; Mantel Requirements; Hearth Requirements; Placing The Insert - Travis Industries AGP PI Installation Instructions Manual

Table of Contents

Advertisement

Installation

Clearances

Insert must be placed so that no combustibles are within, or can swing within (e.g. drapes, doors),
36" (915mm) of the front of the heater.
Insert must be placed a minimum 9"
(229mm) from a side wall (or combustible
protruding more than 3/4" (20mm)).

Mantel Requirements

The mantel must meet the requirements
shown in the illustration to the right.

Hearth Requirements

The non-combustible hearth must extend 6"
to the front and sides of the firebox opening
(you must open the door to measure).

Placing the Insert

The insert must be placed within an
undamaged masonry or factory built (metal)
fireplace. Loose bricks or other damage
must be fixed. Clean the fireplace before
installing.
Side Wall
(229mm)
© Travis Industries
(For Qualified Installers Only)
Min.9"
Minimum 36"
(915mm)
Apply the "This fireplace has been
altered..." sticker to the fireplace. You
may wish to place it in a location where it
will be covered by the surround panels.
4141230
The vent should be routed to
the fireplace prior to installing
the insert. See the section
"Vent Installation" for details
on vent location.
Use the leveling bolts for
fireplaces with recessed
floors. Un-screw the bolts
prior to placing the insert.
Place the insert so the back edge
of the baseplete extends 14-1/4"
(362mm) into the fireplace.
Run the power cord to the side
along the front of the fireplace
(do not route it under the insert).
100-01341
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Agp pellet insert