The Heart of your Home Please read this booklet and keep for future reference for the safe installation of your: LADY KITCHENER (WET) MODEL : AG10 FREESTANDING WOODBURNER AG fires are clean air approved and meet with Ecan standards. This fire has a wetback. All installations must be in accordance with these instructions.
Page 2
Please leave these instructions with owner when installation is complete. INDEX Page No: Item No: Topic: Warnings Installation Responsibilities Floor Protector Requirements Installation Clearances Assembly Instructions Fitting Seismic Restraints Flue Installation Minimum Height of Flue System Exit Wetback Triangular Baffle Bricks Edited 14/11/2012 Lady Kitchener AG10 WET...
Page 3
EFFECTS ON REFACTORY LINING IN SOLID FUEL APPLIANCES. EMISSION OF POISONOUS GASES CAN ALSO BE EXPERIENCED WITH THE BURNING OF TREATED WOOD. Driftwood with salt content will also cause rapid deterioration of the heater and should not be used. Lady Kitchener AG10 WET...
20mm of an approved insulation material i.e. 2 sheets of 10mm micorboard or superlux, 10mm tile backing board and 10mm tiles or similar on the top surface. All joints on the upper surface should be sealed to prevent spilt ash from contacting any heat-sensitive material. Lady Kitchener AG10 WET...
When installing the Lady Kitchener AG on a leg base ADD 70mm to vertical measurements. CLEARANCES ON PED OR 1220 1590 1340 DRAWER ON LEGS 1050 1420 1200 HEATER MUST BE INSTALLED WITH FLUE PIPE SHIELD Lady Kitchener AG10 WET...
Page 6
11. Fit door knob with spacer as per drawing shown herewith - 12. Fit the air control knob - place the flat on the knob to the flat on the shaft situated on the right hand side of the fire. Press home firmly. Lady Kitchener AG10 WET...
3. Secure both the floor protector and the appliance to the floor. LEG MODELS 1. Place firebox on leg assembly and fit brackets. 2. Locate as per appropriate clearances 3. Secure both the floor protector and the appliance to the floor. Lady Kitchener AG10 WET...
Page 8
Note: Ensure ceiling plate is spaced off from the ceiling with ceramic spacers supplied. 16. Fit flue shield – refer page 6. CAUTION: Mixing of appliance or flue system components from different sources or modifying the Lady Kitchener AG10 WET...
Page 9
Where such action is considered the manufacturer should be consulted in the first instance. WARNING: The appliance and flue system shall be installed in accordance with AS/NZS 2918:2001 and the appropriate requirements of the relevant building code or codes. Lady Kitchener AG10 WET...
Page 10
Care must be taken to protect the wetback coil and associated pipework if being installed in a hard/corrosive water area. Damage caused to the Wetback coil if fitted in a hard/corrosive water area will not be covered under the manufacturer’s warranty. Lady Kitchener AG10 WET...
Page 11
LADY KITCHENER AG10 WET IMPORTANT BAFFLES UPON INSTALLATION CHECK THAT TRIANGULAR BRICKS ON TOP OF THE BAFFLES IS PLACED AS SHOWN. BAFFLES Lady Kitchener AG10 WET...