Summary of Contents for Firenzo Forste-Flush-AG-08
Page 1
INSTALLATION AND OPERATOR’S HANDBOOK FOR THE FIRENZO INSERT FLUSH AG08 FIRES CLEAN AIR WOODFIRES Please read this booklet for the safe installation and operation of your: ATHENA FLUSH AG08 ATHENA FLUSH AG08 ATHENA FLUSH ATHENA FLUSH AG08 AG08 FORTE FLUS...
Page 2
This unit has been tested to Appendix E & B of the joint Australia/New Zealand Standard 2918:2001. Please leave this manual with the owner after installation. Your warranty card is enclosed and may be completed and returned to us. INDEX DIAGRAMS: Page 4 Firebox, Fascia &...
Page 3
1. WARNINGS THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS. The Forte Flush AG 08 and the Athena Flush AG08 is tested to N.Z. Standards AS/NZS 2918:2001. If this heater is incorrectly installed a house fire may result. For your safety follow the installation instructions carefully.
2. FLOOR PROTECTOR REQUIREMENTS insulated If the heater is to be placed on or within 500mm of a heat sensitive floor, an floor protector will be required. The insulated floor protector needs to extend under the heater and in front of the door. See dimensions for floor protector.
Page 6
3. BUILT IN FIRE CANOPY A Built In Fire Canopy is required if the fire is not being installed into a masonry fire place. For Built In Fire Canopy installations see the following pages 6,7,8,9,10,11,12,13,14. Flush AG08 Installation...
4. PRE – INSTALLATION (Refer diagram page 4) In a Masonry Fireplace: Before installing your Firenzo Insert it is important to check the condition of your masonry chimney. Ensure any cracks are sealed, loose masonry repaired and the chimney swept.
Page 17
5. ASSEMBLY INSTRUCTIONS Carefully remove all packaging. If installation is into a MASONRY ENCLOSURE: Remove firebricks as necessary to fit the firebox into the opening. The firebox front when installed must be flush with the finished fireplace surround and on a level base of the same height as the finished floor protector.
Page 18
6. INSERT FLUE SYSTEM For Installation in a Masonry Fireplace WARNING; The appliance and flue system must be installed in accordance with AS/NZS 2918:2001 and the appropriate requirements of the relevant building code or codes. 1. Position heater in fireplace. Extend plumb line from top of chimney, ensuring heater spigot is in line with top of chimney.
Page 21
7. FASCIA ASSEMBLY & INSTALLATION ATHENA WITH FLUSH DOOR Remove all items from package and separate. Remove screws fixed to the lugs on the firebox side. Place fascia against body. Position infills each side of the door. Replace screws into body lugs securing the fascia and infills. Refit cast grill.
Page 22
FIRENZO FIRENZO WOODFIRES HEWITSONS LIMITED Manufacturers of: Lady Kitchener Contessa Bronte Viking Royale Zealandia Coaster Athena Forte Plaza Deco 68 Austin Street PO Box 3231 Onekawa Napier Phone: 06 8438260 Fax: 06 8430505 Email: hothouse@firenzo.co.nz Website: www.firenzo.co.nz Flush AG08 Installation...
Need help?
Do you have a question about the Forste-Flush-AG-08 and is the answer not in the manual?
Questions and answers