Toshiba FC-22 Manual page 29

Hide thumbs Also See for FC-22:
Table of Contents

Advertisement

Code
Description/Mode
200
Automatic filling of developer
201
material and automatic ad-
202
justment of the auto-toner cir-
203
cuit
204
221
213 Auto toner output value
223
Developer bias DC (–)
224
output adjustment
225
226
241
Main
charger grid bias
242
output adjustment
243
244
245
Automatic adjustment of the
auto-toner circuit
(Without automatic filling of
developer material)
246
247
248
249
250
252-0
Main charger bias
252-1
output voltage 1 (lower)
252-2
252-3
253-0
Main charger bias
253-1
output voltage 2 (upper)
253-2
253-3
257-0
Developer bias DC (–)
257-1
output voltage 1 (lower)
257-2
257-3
258-0
Developer bias DC (–)
258-1
output voltage 2 (upper)
258-2
258-3
January 2000 © TOSHIBA TEC
Acceptable
Default
Value
All (Y, M, C, K)
0~255
Y
0~255
M
0~255
C
0~255
K
0~255
Color (Y, M, C)
0~255
0
0~1023 Auto toner output value is displayed.
Y
130
0~255
M
130
0~255
C
130
0~255
K
125
0~255
Y
120
0~255
M
120
0~255
C
120
0~255
K
116
0~255
All
0~255
(C, M, Y, K)
0~255
Y
M
0~255
C
0~255
K
0~255
0~255
Color
(Y, M, C)
Y
250
0~999
M
250
0~999
C
250
0~999
K
250
0~999
Y
900
0~999
M
900
0~999
C
900
0~999
K
900
0~999
Y
100
0~999
M
100
0~999
C
100
0~999
K
100
0~999
Y
700
0~999
M
700
0~999
C
700
0~999
K
700
0~999
1 - 21
Contents
After filling the developer from the de-
veloper cartridge (approx. 2.5min.),
auto-toner sensor output is adjusted
(approx. 2min.) to set in the range of
4.00-4.33V. (As the value increases,
the sensor output increases.)
As the value increases, the transformer
output increases. The adjustment value
becomes effective only when the setting
mode (08-400, 401, 409) is 0 (disabled).
As the value increases, the transformer
output increases. The adjustment value
becomes effective only when the setting
mode (08-400, 401, 409) is 0 (disabled).
Auto-toner sensor output is
adjusted (approx. 2 min.) to set
in the range of 4.00~4.33V. (As
the value increases, the sensor
output increases.)
Actual output voltage of main
charger grid bias. After replacing
the main high-voltage transformer,
input the value according to the
supplementary data sheet.
Actual output voltage of developer
bias. After replacing the main high-
voltage transformer, input the value
according to the supplementary
data sheet.
FC-22 ADJUSTMENT
Operation
procedure
group
5
5
5
5
5
5
10
1
1
1
1
1
1
1
1
5
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4