2.SETTING ITEMS (ADMIN)
Setting the copy calibration
1
Press [COPY].
2
Press [DEFAULT] to set the default calibration setting, or [CALIBRATION] to adjust the
calibration setting.
When you press [DEFAULT], the system maintains the default calibration setting and returns to the previous
screen.
When you press [CALIBRATION], the chart is printed out and calibration guide illustration is displayed on the
touch panel.
3
Place the printed chart face down on the glass with its bottom toward you and its top
left aligned against the original scale on the left side, in order that the black line be
placed at the left side.
4
Press the [START] button on the control panel.
When the calibration setting is completed, the GENERAL menu will be displayed.
If the chart is not properly placed, the message "Set chart correctly" is displayed on the touch panel. In this
case, go back to step 3 and place the chart again.
2 SETTING ITEMS (ADMIN)
Setting General Functions