Provide An Adequate Gas Supply; Cooktop Installation - Frigidaire GAS COOKTOP Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

GAS COOKTOP INSTALLATION INSTRUCTIONS
1. Wall Outlet Location

2. Cooktop Installation

1. Visually inspect the cooktop for damage.
2. Set the cooktop into the countertop cutout.
After inserting the cooktop into the countertop opening,
make sure the unit is sitting on the metal flange around
the top of the burner box. Cooktop must not sit on the
glass or the porcelain top. Avoid cutting an oversized
hole in the countertop.
NOTE: Do not use caulking compound; cooktop should
be removable for service when needed.
Granite countertop Installation Kit
A Granite Countertop Installation kit # 903103-9010 can
be ordered through a Sears Service Center.
Clamp Down Information
Once the cooktop is installed in the counter opening,
you must clamp the unit down as shown.
Cooktop
Angle
Bracket
Figure 6
Figure 5
Seal
Countertop
Thumb
Screw
To clamp down, insert an angle bracket into the slot
on each side of the unit as shown. Run thumb screw
up through the bracket, up against the bottom of the
counter. Tighten until the unit draws down and is secure.

3. Provide an Adequate Gas Supply

This cooktop is designed to operate on natural gas at 4"
of manifold pressure only.
A pressure regulator is connected in series with the
manifold on the cooktop and must remain in series with
the supply line.
For proper operation, the maximum inlet pressure to the
regulator must be no more than 14" of water column
(W.C.) pressure.
For checking the regulator, the inlet pressure must be at
least 1" (or 2.5 kPa) greater than the regulator manifold
pressure setting. The regulator is set for 4" of manifold
pressure, the inlet pressure must be at least 5".
The gas supply line to the range should be 1/2" or 3/4"
pipe.
4. LP/Propane Gas Conversion
This appliance can be used with Natural gas or lP/
Propane gas. It is shipped from the factory for use with
natural gas.
A kit for converting to lP gas is supplied with your
cooktop. The kit is marked "FOR lP/PROPANE GAS
CONVERSION".
The conversion must be performed by a qualified
service technician in accordance with the kit instructions
and all local codes and requirements. Failure to follow
instructions could result in serious injury or property
damage. The qualified agency performing this work
assumes responsibility for the conversion.
Failure to make the appropriate
conversion can result in serious personal injury and
property damage.
Important: Remove all packing material and literature
from cooktop before connecting gas and electrical
supply to cooktop.
6

Hide quick links:

Advertisement

Table of Contents
loading