Basic Troubleshooting
Symptom
Acoustic noise or vibration
(e.g. a fan blade is making
noise or vibrations at
certain frequencies)
Table 9.1 Troubleshooting
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
®
VLT
HVAC Drive Operating Instructions
Possible cause
Resonances, e.g. in the motor/fan
system
®
MG11AI02 - VLT
is a registered Danfoss trademark
Test
Bypass critical frequencies by using
parameters in parameter group
4-6* Speed Bypass
Turn off over-modulation in
14-03 Overmodulation
Change switching pattern and
frequency in parameter group
14-0* Inverter Switching
Increase Resonance Dampening in
1-64 Resonance Dampening
Solution
Check if noise and/or vibration
have been reduced to an
acceptable limit