11. HP 1 Source - This drop down is used to select the source for the front panel
HP 1 output.
12. HP 2 Level - This knob controls the output level of the front panel HP 2 output.
13. HP 2 Source - This drop down is used to select the source for the front panel
HP 2 output.
14. S/PDIF Mirrors - The S/PDIF coaxial output may be set to mirror (i.e transmit in
parallel) any of the analog or digital output pairs on the routing grid. Use this pop-
up menu to select the output pair that is mirrored by the S/PDIF coaxial output.
15. Digital Output Meter - This meter displays the level of digital outputs.

Input/Output Tab Windows - Parameter Order

 
Regardless of the type and number of installed I/O Modules, parameters appear in the
Input and Output tab windows in the following order from left to right:
 
1. all analog input or output controls
2. analog speaker and headphone controls
3. S/PDIF Coax Replaces or Mirrors settings
4. digital input or output meters.
 
For example, if an 8 Analog I/O + 8 AES I/O Module is installed in Symphony I/O's
lower slot and a 16 Analog In + 16 Optical Out is installed in the upper slot, parameters
appear in the Input tab window in the following order:
1. 24 analog input controls
2. One S/PDIF Replaces drop-down for each I/O Module
3. 8 AES input meters.
 