Introduction; Controls And Indicators - BK Precision 1601 Instruction Manual

Solid state regulated dc power supply
Table of Contents

Advertisement

The B & K Precision Model 1601 Regulated DC
Power Supply is a versatile, laboratory quality in-
strument which provides regulated dc voltage and
current outputs of 0 to 50 volts and 0 to 2 amperes
respectively. Its high specifications, operating ease,
and special features make it an excellent choice
for most applications requiring a dc power source.
It is especially well suited for powering transis-
torized and fully solid state electronic equipment
such as automobile radios and sound systems, bat-
tery operated radio receivers, portable radios,
mobile citizen's band transceivers and Walkie-Talkie
transceivers.
The following list is 'but a small sample of the
most popular applications for the instrument:
3
1 current meter
2 CURRENT
RANGE switch
0.05A position
0.2A position
0.5A position
2A position
3 SETCURRENT
l
LIMIT control
4
C O N T R O L S A N D I N D I C A T O R S
2
1

Controls and Indicators

Measures actual output load
current during normal oper-
ation.
Indicates current limit value
when set/reset button 4 is
pushed.
Selects range for current
meter 1 and coarse setting
of current limit. Full scale
meter reading and maxi-
mum current limit of:
0.05 ampere (50 milliamps)
0.2 ampere (200 milliamps)
0.5 ampere (500 milliamps)
2 amperes
Fine adjustment of current
limit setting. Continuously
adjustable from 5% to 100%
of range which is selected
by CURRENT RANGE switch
2

INTRODUCTION

Technicians
-Service
-Factory Technicians
-Engineers and
Laboratory
Technicians
-Electronics
Instructors
and Students
13
12
4 Push to set
CURRENT
LIMIT or to reset
OVERLOAD
button (set/
reset button)
5 OVERLOAD
indicator (red)
6 POWER indicator Lights continuously while
7 STBY-DCON
switch;
STBY position
DC ON position
Powering equipment or indi-
vidual circuits during testing
and trouble-shooting in the
service shop.
Powering complete equip-
ments or individual assem-
blies during testing in the
factory.
Powering prototype and ex-
perimental circuits and
equipments.
Laboratory exercises in basic
and advanced electronics.
11
io
When fully depressed and
held, connects current meter
1
to read the current limit
setting. When pressed and
released, resets overload cir-
cuit if it has been tripped.
Lights when current limit has
been exceeded and power
supply output has shut down.
power supply is turned on.
Removes power from output
terminals 9 and 10 and
11 but leaves
voltmeter
power supply activated in a
standby condition.
Applies power to output ter-
9 and
minals
10
11
voltmeter