Lennox XP14 Elite Series Installation Instructions Manual page 9

Xp14 elite series heat pumps
Hide thumbs Also See for XP14 Elite Series:

Advertisement

To hang line set from joist or rafter,
use either metal strapping material
or anchored heavy nylon wire ties.
STRAPPING
MATERIAL
(Around vapor line only)
8 feet
FLOOR JOIST OR
ROOF RAFTER
r\
/
/
WIRE TIE
(Around vapor line only)
TAPE OR
8 feet
WIRE TIE
Strap the vapor line to the joist or
rafter at 8 ft. intervals then strap
the liquid line to the vapor line.
METAL
FLOOR JOIST OR
SLEEVE
ROOF RAFTER
TAPE OR WIRE TIE
Figure 15. Refrigerant Line Sets: Installing Horizontal Runs
NOTE - Similar installation practices should be used if line set is to be installed on exterior of outside wall.
OUTSIDE WALL
IMPORTANT - Refrigerant
lines must not contact wall.
VAPOR LINE
LIQUID LINE
IMPORTANT!
Refrigerant
lines must
not contact
structure.
VAPOR LINE WRAPPED
[_
CAULK
PVC PiPE
FIBERGLASS
iNSULATiON
-_.
WIRE TIE
INSIDE WALL
- STRAP
SLEEVE
WIRE TIE
_"
.---------WOOD
BLOCK
.___----
WIRE TIE
STRAP
SLEEVE
Figure 16. Refrigerant Line Sets: Installing Vertical
Runs (New Construction
Shown)
Page 9
XP14 SERIES