Lennox XP14 Elite Series Installation Instructions Manual page 6

Xp14 elite series heat pumps
Hide thumbs Also See for XP14 Elite Series:

Advertisement

MAINTAIN
MINIMUM
PANEL
ANGLE
(AS C LOSE
TO PARALLEL
WITH
THE UNIT
AS POSSIBLE)
WHILE
INSTALLING
PANEL.
HOLD
DOOR
FIRMLY
TO THE HINGED
ANGLE
MAY BE TOO
SIDE
TO MAINTAIN
EXTREME
--_
FULLY_ENGAGED
TABS
PREFERRED
ANGLE
FOR INSTALLATION
Detail D
Figure 9. Removing/Installing
Louvered Panels
(Detail D)
CAUTION
In the U,S.A.. wiring must conform with current local codes
and the current National Electric Code (NEC). In Canada,
wiring must conform with current local codes and the current
Canadian Electrical Code (CEC),
Refer to the furnace or blower coil installation instructions
for additional wiring application diagrams and refer to unit
nameplate for minimum circuit ampacity and maximum
overcurrent protection size,
1. Install line voltage power supply to unit from a properly
sized unit disconnect switch,
2. Ground the unit at the unit disconnect switch or to
earth ground.
3. To facilitate conduit, a hole is provided in the bottom of
the control box, Connect conduit to the control box
using a proper conduit fitting,
4. Units
are approved
for use
only
with
copper
conductors.
(A complete
unit wiring
diagram
is
located inside the unit control box cover.)
LINE
VOLTAGE
FIELD
INSTALLED
WARNING! - ELECTRIC SHOCK HAZARD. Can cause INJU-
RY or DEATH, Unit must be grounded in accordance with
national and local codes.
Z,/iXX NOTE - For use with copper conductors only. Refer to unit
rating plate for minimum circuit ampacity and maximum over-
current protection size.
Figure 10. Outdoor Unit Typical Field Wiring
NOTE - For proper voltages, select thermostat wire
gauge per the following chart:
Table 2. Wire Run Lengths
Wire run length
AWG #
Insulation type
color-coded, temperature
rating 35°C minimum
less than 100' (30m)
18
more than 100' (30m)
16
5. Install room thermostat
(ordered separately)
on an
inside
wall
approximately
in the
center
of the
conditioned area and 5 feet (1.5 m) from the floor. It
should not be installed on an outside wall or where it
can be affected by sunlight, drafts or vibrations,
6. Install low voltage wiring from outdoor to indoor unit
and from thermostat to indoor unit, See figures 11 and
12 on page 7,
NOTE - 24V, Class II circuit connections are made in the
low voltage junction box,)
,WARNING
Page 6
505244M
04/08