Engine Stopping

Stopping the Engine

Engine Stopping
Stopping the Engine
NOTICE
Stopping the engine immediately after it has been
working under load, can result in overheating and ac-
celerated wear of the engine components.
Avoid accelerating the engine prior to shutting it
down.
Avoiding hot engine shutdowns will maximize turbo-
charger shaft and bearing life.
Note: Individual applications will have different
control systems. Ensure that the shutoff procedures
are understood. Use the following general guidelines
in order to stop the engine.
1. Remove the load from the engine. Reduce the
engine speed (rpm) to low idle. Allow the engine to
idle for five minutes in order to cool the engine.
2. Stop the engine after the cool down period
according to the shutoff system on the engine and
turn the ignition key switch to the OFF position. If
necessary, refer to the instructions that are
provided by the OEM.

Emergency Stopping

NOTICE
Emergency shutoff controls are for EMERGENCY
use ONLY. DO NOT use emergency shutoff devices
or controls for normal stopping procedure.
The OEM may have equipped the application with an
emergency stop button. For more information about
the emergency stop button, refer to the OEM
information.
Ensure that any components for the external system
that support the engine operation are secured after
the engine is stopped.

After Stopping Engine

i02334873
Note: Before you check the engine oil, do not operate
the engine for at least 10 minutes in order to allow the
engine oil to return to the oil pan.
• Check the crankcase oil level. Maintain the oil level
between the "MIN" mark and the "MAX" mark on
the oil level dipstick.
• If necessary, perform minor adjustments. Repair
any leaks and tighten any loose bolts.
• Note the required service interval. Perform the
maintenance that is in the Operation and
Maintenance Manual, "Maintenance Interval
Schedule".
• Fill the fuel tank in order to help prevent
accumulation of moisture in the fuel. Do not overfill
the fuel tank.
Only use antifreeze/coolant mixtures recommended
in the Refill Capacities and Recommendations topic
that is in this Operation and Maintenance Manual.
Failure to do so can cause engine damage.
• Allow the engine to cool. Check the coolant level.
• If freezing temperatures are expected, check the
coolant for the correct antifreeze protection. The
cooling system must be protected against freezing
i01903586
to the lowest expected outside temperature. Add
the correct coolant/water mixture, if necessary.
• Perform all required periodic maintenance on all
driven equipment. This maintenance is outlined in
the instructions from the OEM.