5-2.
VIDEO CARRIER FREQUENCY ADJUSTMENT
Purpose :
Adjusts the carrier frequency when modulating
the video signal.
Adjustment error : Loss of synchronization or loss of color.
Mode
CAM-STANDBY
Signal
Any signal
Measurement Point
TP607 of the IR receiver jig or IC001
pin !§ of IR-28board.
Measuring Instrument
Frequency counter, Oscilloscope
Adjustment Page
F
Adjustment Address
5C
11.83 ± 0.01MHz
Specification Value
Adjustment procedure:
Order
Page
Address
1
6
00
2
6
01
3
6
01
4
F
5C
5
6
6
01
7
6
00
IR-28 BOARD (SIDE A)
24
13
12
25
IC001
36
1
48
37
Data
01
After setting the data, press the PAUSE button. (Preparation)
Read the data pf page : 6, address : 01, and record it.
47
After setting the data, press the PAUSE button.
Change data using PLAY and STOP buttons so that the Y signal level (A) satisfies the
specification. (Record mode)
Press the PAUSE button.
Set the data which is recorded in step 2 to this address and, press the PAUSE button.
00
After setting the data, press the PAUSE button. (End)
Procedure
6-82