Overall Signal Level, Distortion And Separation Check; Overall Noise Level Check - Sony CCD-TRV32 Service Manual

Video camera recorder
Hide thumbs Also See for CCD-TRV32:
Table of Contents

Advertisement

4-6.
OVERALL SIGNAL LEVEL, DISTORTION
AND SEPARATION CHECK
Mode
CAM-REC and playback
1 CN501 pin 4 :400Hz, –38dBs
Signal
* 2 CN501 pin 4 :No signal
Measurement Point
AUDIO output terminal (Left)
*AUDIO output terminal (Right)
Measurement Instrument Audio level meter and distortion
meter
Specification Value
Signal level
(Note)
1 Left output : –7.5 ± 2dBs
* 2 Left output : –27.5dBs or less
Distortion
Left/Right output : 0.8% or less
Note 1 : The value when band-pass filter of 200Hz to 6kHz is used.
Note 2 : Asterisk marks (*) are used in STEREO model.
Check procedure:
Order
Input 400Hz, –38dBs signal to CN501 pin 4. Short pin 2 and 3 of CN501.
1
Check that the right and left channels of AUDIO output terminal satisfy the specification 1.
2
Check that distortion satisfies the specification.
Input 400Hz, –38dBs signal to CN501 pin 2. Short pin 3 and 4 of CN501.
*3
Check that the right and left channels of AUDIO output terminal satisfy the specification 2.
*4
Check that distortion satisfies the specification.
4-7.

OVERALL NOISE LEVEL CHECK

Purpose :
Checks noise level.
Mode
CAM-REC and playback
Signal
No signal : VC-188 board CN501
(Note)
Measurement Point
AUDIO output terminal (Left/Right)
Measuring Instrument
Audio level meter
(using IHF-A curve weighting filter)
Specification Value
–65dBs or less
Note : Before making short circuit between CN501 pin 3 and pin
4, pin 3 and pin 2 (STEREO model only), remove the
flexible board from CN501
Check procedure:
Order
Insert a shorting to pin 3 and pin 4, pin 3 and pin
1
2 (STEREO model only) as CN501.
2
Make recording.
3
Remove the shorting plug.
4
Playback the recorded segment.
5
Confirm that the noise level at audio output terminal
(Left/Right) is –65dBs or less.
CN501 pin 2 : No signal
CN501 pin 2 :400Hz, –38dBs
Right output : –27.5dBs or less
Right output : –7.5 ± 2dBs
Procedure
Procedure
200Hz
18dB/OCT
6-80
6kHz
18dB/OCT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents