3-9.
PB CHROMA LEVEL CHECK
Purpose :
The playback chroma level is kept to constant
level.
Adjustment error : Color of playback picture can be thinner or
thicker than normal picture.
Mode
Playback
Signal
Alignment tape : color bar segment of
operation check tape
• Normal mode
WR5-5CSP (PAL)
WR5-5NSP (NTSC)
CN102 pin 6
Measurement Point
Measuring Instrument
Oscilloscope
Adjustment Page
—
Adjustment Address
—
A=150 ± 15mVp-p
Specification Value
(BURST LEVEL)
Adjustment procedure:
Order
Page
Address
1
—
—
2
—
—
PAL MODEL
A
Before
adjusting
Data
Playback the color bar segment of the normal mode
—
alignment tape.
Check that the burst signal level satisfies the
—
specification.
H H
Procedure
NTSC MODEL
A
H
6-67
White (100%)