16. White balance check

Subject
White pattern standard picture frame
Filter
Color temperature correction filter
C14 ND filter 1.0 and 0.3
Measurement Point
VIDEO output terminal
(Terminated in 75Ω)
Measuring Instrument
Vectorscope
Specification Value
Fig. 6-1-10. A ~ C
Note 1 : Confirm that the "Camera-shaking" correction to OFF.
(EXCEPT TRV14E MODEL)
Note 2 : Confirm that the "Digital Zoom" is turned OFF.
(EXCEPT TRV14E MODEL)
Check procedure:
Order
Page
Address
1
2
6
01
3
4
6
01
5
6
01
6
7
8
9
R-Y
Ø2mm less
2mm
Fig. 6-1-10 (a)
Processing after Adjustments:
Order
Page
Address
1
6
01
2
6
00
Data
Check that the lens is not covered by either filter.
0F
After setting the data, press the PAUSE button.
Check that the white luminance point is located within the circle
shown in Fig. 6-1-10 (a).
00
After setting the data, press the PAUSE button.
23
After setting the data, press the PAUSE button.
Put the C14 filter on the lens.
Check that the white luminance point is located within the circle
shown in Fig. 6-1-10 (b).
Remove the C14 filter and put ND filter 1.3 (1.0+0.3) on the lens.
Check that the white luminance point is located within the circle
shown in Fig. 6-1-10 (c).
R-Y
Ø3mm less
2mm
0.5mm
B-Y
3mm
3mm
Fig. 6-1-10 (b)
Data
00
After setting the data, press the PAUSE button.
00
After setting the data, press the PAUSE button. (End)
Procedure
Ø3mm less
3mm
0.5mm
B-Y
3mm
0.5mm
1.0mm
Fig. 6-1-10 (c)
Procedure
6-24
Condition
Without filter.
C14 filter
ND Filter 1.3
R-Y
1.5mm
B-Y

Hide quick links: