20-2.

VCO adjustment

Purpose :
Sets the VCO free-run frequency.
Adjustment Error : Incorrect picture on EVF
Mode
Stop
Signal
No signal
CN804 pin 4 (HDB) (Type 1, 4)
Measurement point
CN1804 pin 4 (HSY) (Type 2, 3)
Measuring equipment
Frequency counter
Adjustment page
F
Adjustment address
DE
f=15625 ± 30Hz (PAL) (Type 1, 2, 4)
Specification
f=15734 ± 30Hz (NTSC) (Type 3, 4)
Adjustment procedure:
Order
Page
Address
1
2
3
6
00
4
F
DE
5
6
6
00
7
Note :
TYPE 1, 4 (PD-76/SD-24 board)
C183
37
+
38
39
1µF
16V
R821
R819
560
Data
Remove C183/C1804 (1µF capacitor) (Note)
Press the DATA SCREEN button of the remote commander to disappear the display.
01
After setting the data, press the PAUSE button. (Preparation)
Change data using the PLAY and STOP buttons until the oscillating frequency satisfies
the specification.
Press the PAUSE button.
00
After setting the data, press the PAUSE button. (End)
Connect C183/C1804 (1µF capacitor) (Note)
SYNC SEP
IC801
R821 : SD-24 board
R819 : PD-76 board
Type 1
2.5 inch (PAL only)
Type 2
Type 3
3.0 inch (NTSC)
Type 4
3.5 inch (NTSC/PAL)
No mark : Type 1, Type 4
〉 : Type 2, Type 3
Procedure
TYPE 2, 3 (PD-77/SD-25 board)
R1815
560
C1804
Fig. 6-1-17
6-34
LCD size
LCD board
PD-74/SD-24
PD-75/SD-25
PD-77
PD-76
36
35
37
1µF
〈IC1801〉