6 PARAMETER LIST

6.1 Parameter list
In the initial setting, only the simple mode parameters are displayed.
Set Pr. 160 User group read selection as required.
Parameter
Name
160
User group read selection
REMARKS
⋅ The parameters marked
⋅ The parameters marked with
is set in Pr. 77 Parameter write selection.
Parameters
Name
0
Torque boost
1
Maximum frequency 0 to 120Hz
2
Minimum frequency
3
Base frequency
Multi-speed setting
4
(high speed)
Multi-speed setting
5
(middle speed)
Multi-speed setting
6
(low speed)
7
Acceleration time
8
Deceleration time
Electronic thermal
9
O/L relay
DC injection brake
10
operation frequency
DC injection brake
11
operation time
DC injection brake
12
operation voltage
13
Starting frequency
Load pattern
14
selection
15
Jog frequency
Jog acceleration/
16
deceleration time
17
MRS input selection
High speed
18
maximum frequency
Base frequency
19
voltage
*1
The setting depends on capacities. (FR-F720-02330 (FR-F740-01160) or less/FR-F720-03160 (FR-F740-01800) or more)
*2
The setting depends on capacities. (FR-F720-00046/00077 to 00167/00250, 00340/00490 to 01540/01870, FR-F740-00023/00038 to 00083/00126,
00170/00250 to 00770/00930, 01160/01800 or more)
*3
The setting depends on capacities. (FR-F720-00340 ( FR-F740-00170) or less/FR-F720-00490 (FR-F740-00250) or more)
*4
The setting depends on capacities. (FR-F720-00340 (FR-F740-00170) or less/FR-F720-00490 to 02330 (FR-F740-00250 to 01160)/FR-F720-03160
(FR-F740-01800) or more)
Initial
Setting
Value
Range
0
are the simple mode parameters.
in the table allow its setting to be changed during operation even if "0" (initial value)
Setting
Initial
Range
Value
6/4/3/2/
0 to 30%
1.5/1%
120/60Hz
*1
0 to 120Hz
0Hz
0 to 400Hz
60Hz
0 to 400Hz
60Hz
0 to 400Hz
30Hz
0 to 400Hz
10Hz
0 to 3600/360s
5s/15s
0 to 3600/360s 10s/30s
Rated
0 to 500/
inverter
0 to 3600A
*1
current
0 to 120Hz,
3Hz
9999
0 to 10s, 8888
0.5s
0 to 30%
4/2/1%
0 to 60Hz
0.5Hz
0, 1
1
0 to 400Hz
5Hz
0 to 3600/360s
0.5s
0, 2
0
120/60Hz
120 to 400Hz
*1
0 to 1000V,
9999
8888, 9999
9999
Only the simple mode parameters can be displayed.
Simple mode and extended mode parameters can be
0
displayed.
Only the parameters registered in the user group can be
1
displayed.
Parameters
Name
Acceleration/
20
deceleration
*2
reference frequency
Acceleration/
21
deceleration time
increments
Stall prevention
22
operation level
Stall prevention
operation level
23
compensation factor
at double speed
Multi-speed setting
24 to 27
4 speed to 7 speed
*3
Multi-speed input
*3
28
compensation
selection
Acceleration/
29
deceleration pattern
selection
Regenerative
30
function selection
31
Frequency jump 1A
*4
32
Frequency jump 1B
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
PARAMETER LIST
Remarks
Setting
Initial
Range
Value
1 to 400Hz
60Hz
0, 1
0 to 120%, 9999
110%
0 to 150%, 9999
9999
0 to 400Hz,
9999
9999
0, 1
0, 1, 2, 3, 6
0, 2, 10, 20/
0, 1, 2, 10, 11,
20, 21
*1
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0
0
0
0
13