Connect The Cable To The Indoor Unit - Panasonic CS-MZ5SKE Service Manual

Indoor unit
Hide thumbs Also See for CS-MZ5SKE:
Table of Contents

Advertisement

8.2.4

Connect the Cable to the Indoor Unit

1
The inside and outside connection cable can be connected without removing the front grille.
2
Connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 × 1.5
2
mm
flexible cord, type designation 60245 IEC 57 or heavier cord.
3
Bind all the indoor and outdoor connection cable with tape and route the connection cable via the
escapement.
4
Remove the tapes and connect the connection cable between indoor unit and outdoor unit according to the
diagram below.
Terminals on the outdoor unit
Colour of wires
Terminals on the indoor unit
Connection cable
Indoor & outdoor
Connection cable
Escapement
Recommended
length (mm)
a b c d e
Recommended
length (mm)
35 35 35 55 60 40 35 60
Note:
Secure the connection cable onto the control board with the holder.
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor's respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason.
8.2.4.1
Wire Stripping, Connecting Requirement
Wire stripping
No loose strand
when inserted
*For MZ5****
L
N
Tape
Indoor & outdoor
connection cable
Outdoor unit
f
g h
Indoor/outdoor
connection
terminal board
5 mm
or more
(gap between wires)
1
2
3
1
2
3
Terminal
Board
Earth Wire
longer than
others
AC wires
for safety
reason
Holder
WARNING
This equipment must
be properly earthed.
26
*For other indoor models
L
N
1
L
1
N
S1
Terminal Board
Indoor & outdoor
connection cable
Outdoor unit
Conductor
Conductor
fully inserted
over inserted
ACCEPT
PROHIBITED
2
3
2
3
Control
Board
Earth wire
longer than
others
AC wires
for safety
reason
Holder
Tape
Connection cable
Conductor not
fully inserted
PROHIBITED

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-mz5ske-m