9. Floor-Standing Type (F Type)
Unit specifications (C)
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity
Air circulation (Hi / Me / Lo)
Moisture removal (High)
ELECTRICAL RATINGS
Voltage rating
Available voltage range
Running amperes
*
Power input
Power factor
Max. starting amperes
FEATURES
Controls / Thermostat control
Timer
Fan speeds
Air filter
Refrigerant control
Operation sound (Hi / Me / Lo)
Refrigerant tubing connections
Refrigerant tube
outer diameter
Drain connection
Drain pump
Drain pump (drain connection)
Remote controller (option)
DIMENSIONS & WEIGHT
Dimensions
Net weight
Shipping weight
Shipping volume
Cooling :
Rating conditions(
) :
*
Heating :
Rating conditions(
) :
*
Indoor Unit
kW
BTU / h
3
m
/ h
Liters / h
V
V
A
W
%
A
dB-A
Narrow tube mm (in)
Wide tube
mm (in)
Height
mm (in)
Width
mm (in)
Depth
mm (in)
kg (lb)
kg (lb)
m
3
(cu. ft)
Indoor air temperature 27 °C DB / 19 °C WB, Outdoor air temperature 35 °C DB
Indoor air temperature 20 °C DB, Outdoor air temperature 7°C DB / 6°C DB
I - 109
ECO MULTI SYSTEM Unit Specifications
SPW-F183GH56
220 - 230 - 240 V / 1 phase / 50Hz
Cooling
5.6
19,000
900 / 780 / 660
3
220
230
240
198 – 264
0.54
0.56
0.58
116
126
136
97.6
97.8
97.7
1
1
1
Microprocessor / I.C. thermostat
ON / OFF Timer (Max.72 hr)
3 and Automatic control
Washable, easy access
Electronic refrigerant control valve
39 / 36 / 31
Flare type
9.52 (3 / 8)
15.88 (5 / 8)
20A, OD26mm
Optional (RCS-SH80TG)
Optional / drain hose
Unit dimensions
615 ( 24 - 7 /32)
1380 ( 54 - 11 /32)
230 ( 9 - 2 /32)
39 (
41 (
0.319 (
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Heating
6.3
21,000
220
230
240
198 – 242
0.37
0.41
0.43
79
91
101
97.1
96.5
97.9
1
1
1
Package dimensions
694 (27 --10/32 )
1472 (57 --30/32 )
312 ( 12 - 9 /32)
86
)
90
)
11.3
)
SM830052
1

Hide quick links: