2.8

Removal of the Compressor

Procedure
Step
1
Remove the terminal
cover.
2
Disconnect the lead
wires of the
compressor.
188
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Terminal cover
SiEN04-306D
Points
(R2741)
Be careful so as not to burn
the compressor terminals or
the name plate.
Make a note.
U
V
W
U : red
V : yellow
W : blue
N : brown
Removal Procedure
N