1.3

Removal of the Horizontal Blades / Vertical Blades

Procedure
Step
1. Remove the horizontal
blades.
1
Open the horizontal
blades.
2
Undo the left pivot of
the horizontal blades.
3
Bend the horizontal
blades slightly and
release the center
pivots.
Slide the horizontal
blades to the left and
release the right pivot.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Horizontal blades
Left pivot
(R2763)
(R2764)
Center pivot
(R2765)
Right pivot
(R2766)
Indoor Unit
Points
It has no fixing screws inside
blades, though previous
models had.
Installation procedure
1. Since key pattern hook is
provided, rotate the blades
and fit it to the right pivot
first.
2. Fit the blades to the center
and left pivots.
153