III. DAMPERS
A. Are blades and seals present? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Yes
B. Do damper open smoothly and shut tight?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Yes
IV. ELECTRIC HEAT
A. Electrical heat service corresponds to unit nameplate? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Yes
B. Are there any signs of physical damage to the electric heat coils? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Yes
C. Have all electrical terminals been tightened? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Yes
D. Does sequence controller stage contactors properly? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Yes
E. Electric heater voltage across each phase: ___________ L1
F. Amp draw across each phase at each heating stage:
Stage 1
Phase L1:
___________
Phase L2:
___________
Phase L3
___________
G. FLA: L1 ___________
H. Operate electric heat with fans off. Electric heat must cycle on high limit control . . . . . . . . . . . . . . . . . . . . . . . .Yes
V. CHILLED WATER
A. Pressure test OK? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Yes
B. Drain pan draining OK?
VI. HOT WATER COIL
A. Pressure test OK? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Yes
VI. HEAT RECOVERY
A. Heat wheel rotates freely? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Yes
B. Heat wheel VFD operates properly? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Yes
C. Heat wheel VFD:
D. Check for air bypass around heat wheel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Yes
Comments:
Performed by: ______________________________________________ Title: ________________________________
Signature: _________________________________________________ Date of start-up: _______________________
Return completed form by mail to:
Daikin Applied Warranty Department
13600 Industrial Park Boulevard
Minneapolis, MN 55441
or by email to:
AAH.Wty_WAR_forms@DaikinApplied.com
Please list any additional comments that could affect the operation of this unit; e.g., shipping damage, failed components, adverse
installation applications, etc., on a separate sheet and attach to this form or within the email message.
Form Number: 415416Y (02/13)
IM 777-8 • Skyline Air Handler
Volts _____________ Hertz _____________ Phase _____________
Stage 2
Stage 3
____________
____________
____________
____________
____________
____________
L2____________
L3 ___________
Model # _________________________
C
, T
heCk
esT and
Air Handling Equipment Warranty Registration Form (continued)
___________ L2
___________ L3
Stage 4
Stage 5
___________
___________
___________
___________
___________
___________
Serial # _________________________
44
W
r
arranTy
eGIsTraTIon
No
N/A
No
N/A
No
N/A
No
N/A
No
N/A
No
N/A
Stage 6
____________
____________
____________
No
N/A
No
N/A
Yes
No
N/A
No
N/A
No
N/A
No
N/A
No
N/A
www.DaikinApplied.com