Display Active Alarms; Display Alarm History - Quintum Tenor AS Product Manual

Tenor as voip multipath/gateway switch
Table of Contents

Advertisement

Chapter 5: Advanced Topic: Diagnostics/Maintenance

Display Active Alarms

You are able to display all active alarms as follows:
1. Through CLI, access the Monitor prompt.
2. Type alarm a. The active alarms will be listed. See section
tions. If you enter alarm without a command following it, both active alarms and the alarm his-
tory will be displayed.
IP# Sequence#Type#Severity# Desc# Slot# Device#Analog Interface# Channel# Date/Time
192.166.28.230:944:ALR:3:Border Element connection lost:0:0:0:0:TUE OCT 14 14:05:27 2003

Display Alarm History

1. Through CLI, access the Monitor prompt.
2. Type alarm h. An alarm history will be displayed. See section How to Read Alarms for field def-
initions. If you enter alarm without a command following it, both active alarms and the alarm
history will be displayed.
IP# Sequence#Type#Severity# Desc# Slot# Device# Analog Interface# Channel# Date/Time
192.166.28.230:944:ALR:3:Border Element connection lost:0:0:0:0:TUE OCT 14 14:05:27 2003
192.166.28.230:945:RPT:4:Gatekeeper status (Gatekeeper(192.168.20.175) removed):0:0:0:0:TUE OCT 14
14:05:27 2003
192.168.20.175:946:RPT:4:Gatekeeper status (Gatekeeper(0.0.0.0) removed):0:0:0:0:TUE OCT 14
5-7
Figure 5-2 Active Alarm Sample
Figure 5-3 Alarm History Sample
How to Read Alarms
for field defini-
P/N 480-0059-00-10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents