2. Safety
Please observe the installation instruction and the following safety warnings.
1.
Installation and connection of the IUPS-401-B1 must only be carried out by a
qualified electrical technician. The relevant rules of electrical engineering must
be observed. For powering the UPS units only the included power cord must
be used.
2.
The IUPS is only approved for installation and operation in a chassis. Before the
installation disconnect mains and make sure that the system is voltage-free.
3.
During the installation make sure the IUPS-401-B1 is safely mounted. Only use
the included screws for mounting the unit. Make absolutely sure that no screws
that are longer than the included ones are used.
4.
The batteries must only be exchanged by a qualified electrical technician.
5.
Make sure that the combined leakage current of the IUPS-401-B1 and
the connected consumer load does not exceed 3.5 mA.
Warning, danger of electric shock!
Even when mains is disconnected components within the
UPS are supplied by the battery and contain dangerous
voltages. For any work at the unit disconnect the internal
battery connectors.
16
User's Manual IUPS-401-B1
User's Manual IUPS-401-B1

3. Installation Instruction

To optimize the service life of the battery install the IUPS into the computer at a
location with preferably low temperature..
1. Disconnect mains
3. Connect 5-pole control cable at the IUPS
5. Connect the IUPS mains cable with the power
supply of the computer
2. Install slot bracket with 5-pole control cable
4. Connect mains cable of the IUPS and the special
IUPS cable
6. Connect mains plug with the IUPS mains cable
17