Ref.No.
Name
S100
TEST OUT signal select switch
n
The table below shows selectable output signals in combination with S100-1 through S100-4
and depending on whether the RET CONT signal is low or high
S100-1
PB VIDEO/RET
S100-2
VBS/RET
S100-3
MONITOR/VBS
S100-4
RET CONT
Selecting TEST OUT signal
S100-1
S100-2
OFF
OFF
ON
OFF
X
ON
X
ON
OFF
ON
OFF
ON
X: Don't care.
CA-570 P1
Description
Disables automatically switching between PB VIDEO and RET VIDEO
signals when S100-1 is set to ON
Disables automatically switching between VBS/MONITOR and
PB/RET VIDEO signals when S100-2 is set to ON
Selects MONITOR or VBS signal
Inhibits the RET CONT signal when S100-4 is set to OFF
S100-3
S100-4
X
X
X
X
OFF
OFF
ON
OFF
OFF
ON
ON
ON
RET CONT
Output signal at TEST OUT connector
X
RET VIDEO OUT (in connection with CCU)
PB VIDEO OUT (in connection with VTR)
X
PB VIDEO OUT
X
VBS OUT
X
MONITOR OUT
Low
RET VIDEO OUT (in connection with CCU)
Low
PB VIDEO OUT (in connection with VTR)
High
VBS OUT
Low
RET VIDEO OUT (in connection with CCU)
Low
PB VIDEO OUT (in connection with VTR)
High
MONITOR OUT
1-4. Function of Internal Switches
Factory setting
OFF
OFF
OFF
ON
1-15 (E)