Hearths, Fire Surrounds and Shelves
The
fl oor
o r
r ecess
o n
w hich
t he
fi re
s tands
s hall
h ave
a dequate
l oad
b earing
c apacity.
P articular
a ttention
s hall
be paid to existing constructions.
It
i s
i mportant
t o
e nsure
t hat
t he
fi replace
i s
i nstalled
o n
a
n on-combustible
s urface.
Do
n ot
i nstall
t his
u nit
d irectly
o nto
w ooden
o r
c arpet
fl oors.
Any
fi re
s urround
o r
h earth
s hould
b e
s uitable
f or
u se
w ith
a
s olid
f uel
fi re.
Allowances
m ust
b e
m ade
f or
e xpansion
a nd
c ontraction
w hen
fi tting
m aterials
u p
a gainst
t he
fi re
w hich
m ay
become hot.
Hearths
The construction of hearths must be in line with the Building Regulations Document J.
Both the constructional hearth and the superimposed hearth must be made from non combustible material.
The constructional hearth must be at least 125mm thick and protrude 500mm forward from the front face of the
appliance and 150mm each side from the edge of the appliance. See diagram.
The superimposed hearth must be 225mm forward from the front face of the appliance and 150mm each side
from the edge of the appliance. See diagram.
FIRE FRAME
150
150
SUPERIMPOSED
CONSTRUCTIONAL
HEARTH
HEARTH
New
hearths,
fireplaces
recesses
and
chimneys
should
be
constructed
to
conform
to
Building
Regulations
Document J.
Hearths,
o r
p linths
c onstructed
t o
s upport
t he
fi re
a bove
t he
h earth,
m ust
b e
h orizontal.
Any
h ole
i n
t he
w all
i nstallation
w ill
s till
r equire
a
h earth
t o
b e
fi tted.
Fire Surrounds
Some
fire
surrounds
require
the
fire
to
be
set
forward
from
the
chimney
breast
or
to
be
raised
for
aesthetic
reasons.
E nsure
t hat
t hese
r equirements
a re
t aken
i nto
a ccount
w hen
p ositioning
t he
fi re.
T ake
t his
i nto
a ccount
when
f orming
t he
r ecess
a nd
f ront
fi nished
f ace
o f
t he
fi replace
f or
t he
fi re.
T he
m inimum
d istance
t o
t he
e dge
of
a ny
fi re
s urround
f rom
t he
e dge
o f
t he
fi re
f rame
m ust
b e
m inimum
2 00mm
( 8").
Protection of Heat and Shelves
As
on
all
heat
producing
appliances
the
use
of
flammable
wall
coverings
directly
above
or
to
the
sides
of
the
fire
may
lead
to
a
fire
hazard.
Please
bear
this
in
mind
when
installing
the
appliance
or
decorating.
Due
to
the
e xtreme
t emperatures
t hat
c an
b e
a chieved
a bove
t he
fi re
a lways
e nsure
t hat
a ny
T V's,
p aintings
o r
o ther
combustible
i tems
t hat
m ay
b e
n ear
d o
n ot
b ecome
e xcessively
h ot.
F or
T V's
a lways
c onsult
t he
m anufacturers
instructions to see if exposure to heat will cause damage.