B-32
One of these four items will blink to indicate which item
will change when the Mode Select Panel Knob is rotated.
Initially, the selected item will be the attribute. To select
the high limit, press either Mode Select Panel button and
the high limit value will begin to blink. Pressing either
Mode Select Panel button again will cause the memory
value to blink, pressing a third time will cause the low
limit to blink.
Weld modes cannot be selected from the Limits Setup
menu; the mode must be selected and saved to memory
prior to entering the Limits Setup menu.
The memory value, high and low limit values are bound
by the limits of the machine. For example, weld mode 49
may allow the wire feed speed to be adjusted between
100 and 700 in/min. These are referred to as "machine
limits". Machine limits can vary between power sources
and are also weld mode dependent.
The memory value must always be less than or equal to
the high limit and greater than or equal to the low limit.
The high limit must always be greater than or equal to
the low limit and the low limit must always be less than or
equal to the high limit. The rules are enforced automati-
cally. If the low limit is increased above the memory
value, the memory value will automatically increase.
To lock an attribute to a specific value, set the high and
low limits to the desired value. The user will not be able
to change it.
After setting limits, press the memory button that is flash-
ing. The Mode Select Panel displays will prompt the
user to save or discard the limit changes just made.
By pressing the Mode Select Panel button labeled YES,
changes to limits are saved and user limits are automati-
cally enabled. By pressing NO, any changes made to
limits are discarded and the limit enable/disable state is
not changed.
WAVEFORM CONTROL TECHNOLOGY
IR PORT
Yes
WELD MODE
ARC CONTROL
To enable or disable limits that have been established for
any memory, press and hold the respective memory but-
ton in for more than 10 seconds until the Mode Select
Panel displays "Enable Limits?" Pressing "Yes" will use
the established limits, while pressing "No" will ignore the
established limits. The limits that have been set for any
memory location will not be erased if they are disabled.
OPERATION
Enable
Limits?
SETUP
No
START OPTIONS
END OPTIONS
SET
POWER FEED
®
10M SINGLE WIRE FEEDER
B-32