B-25
MACHINE FUNCTIONALITY BY WELD PROCESS
CV GMAW/FCAW (NON-SYNERGIC)
Use the following tables to review how the machine functions (output controls, arc control, Start options and weld
options) for the weld modes listed in the top table.
OUTPUT CONTROL KNOBS, WELD MODE 5 & 6
300
WFS
AMPS
LESS
MORE
WFS
WFS
CV NON-SYNERGIC MODES
Material
PROCESS
Steel
GMAW, CV
Steel
GMAW, POWER MODE
Steel
FCAW, CV
WAVEFORM CONTROL TECHNOLOGY
5
IR PORT
STD CV MIG
WELD MODE
ARC CONTROL
SET
ARC CONTROL
EFFECT / RANGE
(Soft)-10.0 to
Arc Force adjusts the short cir-
(Crisp)+10.0
cuit current for a soft arc, or for
a forceful, digging arc.
OPERATION
25.3
VOLTS
TRIM
LESS
MORE
VOLTS
VOLTS
WELD MODE
5
40
6
SETUP
START OPTIONS
END OPTIONS
DESCRIPTION
POWER FEED
®
10M SINGLE WIRE FEEDER
OUTPUT CONTROL KNOBS, WELD MODE 40
200
WFS
AMPS
LESS
MORE
WFS
WFS
START OPTIONS
The start Options available in these Non-Synergic CV weld
modes, their adjustment range and function are as follows :
EFFECT / RANGE
Preflow Time
Adjusts the time the gas flows
0 to 25.0 seconds
after the trigger is pulled and
prior to feeding.
Run-In WFS:
Run-In sets the wire feed
Off, 30 to150 in/min.
speed from the time the trigger
is pulled until an arc is estab-
lished.
Start Procedure
The Start Procedure controls the
0 to 10 seconds
WFS and Volts for a specified time
at the beginning of the weld.
During the start time, the machine
will ramp up or down from the
Start Procedure to the preset
Welding Procedure.
END OPTIONS
EFFECT / RANGE
Spot Timer:
Adjusts the time welding will continue
0 to 120.0 Seconds
even if tigger is still pulled. This option
has no effect in 4-Step Trigger Mode.
Postflow Time
Adjusts the time that shielding gas
0 to 25.0 seconds
flows after the welding output turns off.
Crater Procedure
Crater Procedure controls the WFS
(0 TO 10.0 SECONDS)
and Volts for a specified time at the
end of the weld after the trigger is
released. During the Crater time, the
machine will ramp up or down from the
Weld Procedure to the Crater
Procedure.
Burnback:
The burnback time is the amount of
0 to .25 Seconds
time that the weld output continues
after the wire stops feeding. It prevents
the wire from sticking in the puddle and
prepares the end of the wire for the
next arc start.
B-25
2.0
VOLTS
TRIM
LONGER
SHORTER
ARC
ARC
DESCRIPTION
DESCRIPTION

Hide quick links:

Advertisement

Table of Contents
loading