E-2
PROBLEMS
(SYMPTOMS)
LINC-NET SYSTEM ERROR CODES
Err 006
Err 100
ARCLINK SYSTEM ERROR CODES
Err 31 Primary overcurrent
Err 32 Capacitor bank "A" under
voltage.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE
1. The wire feeder has not received
a recognition command from the
power source. Verify the power
source is operating properly
(Status light steady green.)
2. Check control cable for loose or
broken leads.
3. See power source Instruction
Manual.
1. The power source has issued a
shutdown command. Verify the
power source is operating proper-
ly. (Status light steady green.)
2. Check control cable for loose or
broken leads.
3. See power source instruction
Manual.
1. The power source has exceeded
input current limits. Adjust the
welding procedure to reduce the
current draw. The welding proce-
dure may exceed the capacity of
the power source.
2. See the power source Instruction
Manual.
1. The power source input power
may be wired incorrectly. Verify
the power source reconnect
panel wiring matches the input
power.
2. See the power source Instruction
Manual.
POWER FEED
®
10M SINGLE WIRE FEEDER
CAUSE
If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.
CAUTION
RECOMMENDED
COURSE OF ACTION
E-2